...
首页> 外文期刊>The Journal of Bone and Joint Surgery. American Volume >Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing Results After a Minimum of Twenty Years of Follow-up
【24h】

Primary Cementless Total Hip Arthroplasty with an Alumina Ceramic-on-Ceramic Bearing Results After a Minimum of Twenty Years of Follow-up

机译:经过至少二十年的随访,采用氧化铝陶瓷-陶瓷轴承的非骨水泥全髋关节置换术

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The biological problems related to wear debris after total hip arthroplasty have stimulated renewed interest in alternatives to metal-on-polyethylene bearing surfaces. Methods: We retrospectively evaluated the clinical and radiographic results of 100 patients who had undergone a total of 109 primary total hip arthroplasties with a cementless alumina ceramic-on-ceramic prosthesis between January 1985 and December 1989. The mean age of the patients at the time of the index arthroplasty was forty-six years. Clinical evaluation was performed with use of the Charnley modification of the Merle d'Aubigne-Postel scale. Seventy-eight patients who had had a total of eighty-five arthroplasties were available for follow-up evaluation at an average of 20.8 years. The patients' average age at the time of the latest follow-up was 66.8 years. Results: Six hips (six acetabular cups and one femoral stem) in six patients underwent revision. Aseptic loosening of the cup combined with focal osteolysis was the cause of all six revisions. In one patient, the stem was also revised because of aseptic loosening. At the time of final follow-up, the result was excellent (according to the Merle d'Aubigne-Postel scale) in 68% of the hips, good in 19%, fair in 9%, and poor in 4%. The mean Merle d'Aubigne-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (p < 0.001). The cumulative rate of survival of the prostheses was 84.4% at 20.8 years. Conclusions: The results of these cementless ceramic-on-ceramic total hip arthroplasties continued to be satisfactory at a minimum of twenty years postoperatively. The improved design of contemporary prostheses and the new generation of ceramic-on-ceramic bearing surfaces may lead to even better long-term results. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
机译:背景:与全髋关节置换术后的磨损碎片有关的生物学问题激发了人们对替代金属对聚乙烯轴承表面的兴趣。方法:我们回顾性评估了1985年1月至1989年12月间共进行了109例初次全髋关节置换术并使用非水泥氧化铝陶瓷-陶瓷假体的100例患者的临床和影像学结果。当时患者的平均年龄关节置换指数为46年。临床评估是通过使用Merle d'Aubigne-Postel量表的Charnley修改进行的。总共进行了85例关节置换术的78例患者可进行平均20.8年的随访评估。最近一次随访时患者的平均年龄为66.8岁。结果:6例患者的6个髋关节(6个髋臼杯和1个股骨柄)接受了翻修。所有六个翻修的原因是杯的无菌性松动和局灶性骨溶解。在一名患者中,由于无菌性松动,其茎也进行了翻修。在最后一次随访时,结果(根据Merle d'Aubigne-Postel量表)为68%的髋部为佳,有19%的髋关节良好,有9%的髋关节为佳,有4%的髋关节为差。 Merle d'Aubigne-Postel平均得分从术前的7.9分提高到术后的16.9分(p <0.001)。假体在20.8年的累积生存率为84.4%。结论:这些非骨水泥陶瓷-陶瓷全髋关节置换术的结果在术后至少二十年内仍令人满意。现代假体的改进设计和新一代陶瓷-陶瓷支承表面可能会带来更好的长期效果。证据级别:治疗级别IV。有关证据水平的完整说明,请参见《作者须知》。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号