BACKGROUND: While most reports of component fracture following alumina-on-alumina total hip arthroplasty have involved the acetabular liner, few have involved fracture of the alumina femoral head. In the present multicenter study, we investigated ceramic head fractures in a cohort of patients who underwent third-generation alumina-on-alumina total hip arthroplasty. METHODS: We performed a retrospective study of 312 patients (367 hips) who underwent alumina-on-alumina total hip arthroplasty without cement at four participating centers with the use of a 28-mm BIOLOX forte femoral head and a BIOLOX forte liner from July 2001 to October 2003. Three hundred and five patients (359 hips) were evaluated at a mean of forty-five months postoperatively. Clinical follow-up with use of the Harris hip score and radiographic evaluation were performed at six weeks; at three, six, and twelve months; and every six months thereafter. Retrieved ceramic implants were examined by means of visual inspection. RESULTS: Five hips (1.4%) in five patients were revised because of a ceramic head fracture during the follow-up period. The ceramic head fractures occurred during normal daily activities at a mean of 22.6 months postoperatively. A short neck had been used in all five hips in which a fracture occurred, compared with 121 (34.2%) of the 354 hips in which a fracture did not occur (p = 0.009). The fracture involved a circular crack along the circumference of the thinnest portion of the head component at the proximal edge of the bore. The fracture also involved multiple vertical cracks extending radially along the longitudinal axis from the circumference of the circular crack line to the lower edge of the head component. CONCLUSIONS: In the present study, the rate of ceramic head fracture associated with one design of a short-neck modular alumina femoral head was 1.4% (five of 359). The extent to which these findings are generalizable to other designs that utilize this type of femoral head is unknown.
机译:背景:虽然大多数关于氧化铝对氧化铝的全髋关节置换术后部件断裂的报道涉及髋臼内衬,但很少涉及氧化铝股骨头的断裂。在当前的多中心研究中,我们调查了接受第三代氧化铝对全髋关节置换术的患者队列中的陶瓷头骨折。方法:我们进行了一项回顾性研究,从2001年7月开始在四个参与中心对312例患者(367髋)进行了不加水泥的氧化铝-氧化铝全髋关节置换术,并使用了28 mm BIOLOX股骨头和BIOLOX复数内衬到2003年10月。平均术后45个月对355例患者(359髋)进行了评估。在六周时进行了哈里斯髋关节评分和影像学评估的临床随访。在三个,六个和十二个月时;此后每六个月一次。通过目测检查回收的陶瓷植入物。结果:5例患者的5个髋关节(1.4%)因在随访期间发生陶瓷头骨折而进行了翻修。陶瓷头骨折发生在正常的日常活动中,平均术后22.6个月。在发生骨折的所有五个髋部均使用了短颈,相比之下,未发生骨折的354个髋部中有121个(34.2%)(p = 0.009)。骨折包括沿孔的近端边缘处头部组件最薄部分的圆周的圆形裂纹。骨折还涉及多个垂直裂纹,这些裂纹沿纵向轴线从圆形裂纹线的圆周向头部组件的下边缘沿径向延伸。结论:在本研究中,与一种设计的短颈模块化氧化铝股骨头相关的陶瓷头骨折率为1.4%(359个中的五个)。这些发现可推广到其他利用这种类型的股骨头的设计的程度尚不清楚。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号