...
首页> 外文期刊>The Journal of Bone and Joint Surgery. American Volume >The effects of intratendinous and retrocalcaneal intrabursal injections of corticosteroid on the biomechanical properties of rabbit Achilles tendons.
【24h】

The effects of intratendinous and retrocalcaneal intrabursal injections of corticosteroid on the biomechanical properties of rabbit Achilles tendons.

机译:腹膜内和跟骨后跟皮内注射皮质类固醇对家兔跟腱生物力学特性的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The use of corticosteroid injections in the treatment of retrocalcaneal bursitis is controversial. We assessed the effects of corticosteroid injections, both within the tendon substance and into the retrocalcaneal bursa, on the biomechanical properties of rabbit Achilles tendons. The systemic effects of bilateral corticosteroid injections were also studied. METHODS: The rabbits were divided into three treatment groups. The rabbits in Group I received injections of corticosteroid into the Achilles tendon on the left side and injections of normal saline solution into the Achilles tendon on the right, those in Group II received injections of corticosteroid into the retrocalcaneal bursa on the left side and injections of saline solution into the Achilles tendon on the right, and those in Group III received injections of corticosteroid into the Achilles tendon on the left side and injections of corticosteroid into the retrocalcaneal bursa on the right. These injections were given weekly for three weeks. At four weeks after the final injection, the tendons were harvested and were tested biomechanically to determine failure load, midsubstance strain and total strain, modulus of elasticity, failure stress, and total energy absorbed. The site of failure was also documented. The groups were compared according to the location of the injections, the type of injection (steroid or saline solution), and the total systemic load of steroid. RESULTS: Specimens from limbs that had received intratendinous injections of corticosteroid showed significantly decreased failure stress compared with those from limbs that had received intratendinous injections of saline solution (p = 0.008). Specimens from limbs that had received intrabursal injections of corticosteroid demonstrated significantly decreased failure stress (p = 0.05), significantly decreased total energy absorbed (p = 0.017), and significantly increased total strain (p = 0.049) compared with specimens from limbs that had received intratendinous injections of saline solution. Specimens from limbs that had received intratendinous injections of corticosteroid were biomechanically equivalent to specimens from limbs that had received intrabursal injections of corticosteroid. Specimens from rabbits that had received bilateral injections of corticosteroid demonstrated significantly decreased failure load (p = 0.011), modulus of elasticity (p = 0.015), failure stress (p = 0.03), and total energy absorbed (p = 0.015) compared with those from rabbits that had received unilateral injections of steroid. CONCLUSIONS: Local injections of corticosteroid, both within the tendon substance and into the retrocalcaneal bursa, adversely affected the biomechanical properties of rabbit Achilles tendons. Additionally, tendons from rabbits that had received bilateral injections of corticosteroid demonstrated an additive adverse effect, with significantly worse biomechanical properties compared with tendons from rabbits that had received unilateral injections of corticosteroid.
机译:背景:皮质类固醇激素注射剂用于治疗跟骨后滑囊炎是有争议的。我们评估了在肌腱物质内和跟骨后囊中注射皮质类固醇对兔跟腱生物力学特性的影响。还研究了双侧皮质类固醇注射的全身作用。方法:将兔分为三个治疗组。第一组的兔子在左侧的跟腱中注射皮质类固醇,右侧的跟腱注射生理盐溶液,第二组的兔子在左侧的跟骨后囊中注射皮质类固醇,并注射右脚跟腱中加入盐溶液,第三组的左脚跟腱中注射了皮质类固醇,右脚跟骨的后跟法囊中注射了皮质类固醇。每周进行这些注射,持续三周。在最后一次注射后的四个星期,收集肌腱并进行生物力学测试,以确定破坏载荷,中物质应变和总应变,弹性模量,破坏应力和吸收的总能量。还记录了故障地点。根据注射位置,注射类型(类固醇或盐溶液)和类固醇的总全身负荷对两组进行比较。结果:与定期注射生理盐水的肢体相比,接受糖皮质激素定期注射的肢体的破坏应力显着降低(p = 0.008)。与已接受四肢的标本相比,接受囊内注射皮质类固醇注射的四肢标本显示出明显降低的衰竭压力(p = 0.05),显着降低的总吸收能量(p = 0.017)和显着增加的总应变(p = 0.049)。定期注射生理盐水。接受了糖皮质激素常规注射的四肢标本在生物力学上等同于接受了囊内激素注射的皮质四肢标本。与双侧注射皮质类固醇激素的兔子相比,它们的失败负荷(p = 0.011),弹性模量(p = 0.015),失败应力(p = 0.03)和吸收的总能量(p = 0.015)明显降低。接受单侧类固醇注射的兔子身上结论:在肌腱内和跟骨后囊均局部注射皮质类固醇激素,对兔跟腱的生物力学特性产生了不利影响。此外,与单侧注射皮质类固醇的兔子的肌腱相比,双侧注射皮质类固醇的兔子的肌腱表现出累加的不良作用,其生物力学性能明显更差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号