Minimum ten-year follow-up of a straight-stemmed, plasma-sprayed, titanium-alloy, uncemented femoral component in primary total hip arthroplasty.

机译:在原发性全髋关节置换术中,对直梗,等离子喷涂,钛合金,非骨水泥化股骨组件进行至少十年的随访。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The long-term results of total hip arthroplasty without cement have been reported only rarely. The purpose of the present study was to evaluate the minimum ten-year results of primary total hip arthroplasty performed with use of a proximally porous-coated, plasma-sprayed, straight-stemmed, titanium-alloy femoral component. METHODS: The clinical and radiographic results of a consecutive series of 105 total hip replacements in ninety-five patients were reviewed ten to twelve years postoperatively. The diagnosis was osteoarthritis for seventy-seven hips (73%). The clinical result was evaluated on the basis of the Harris hip score, complications, and thigh pain. A detailed radiographic analysis was performed at each follow-up visit. Kaplan-Meier analysis was performed to evaluate the survival of the femoral component. RESULTS: The average Harris hip score improved from 46 points preoperatively to 92 points postoperatively. The average pain score at the time of the most recent follow-up was 42 points, with eighty-three hips (79%) rated as pain-free. Thigh pain was identified in only two patients. All radiolucent lines were seen around the tip of the stem. All hips had some degree of femoral remodeling consistent with osseous ingrowth. No femoral component was revised, and no femoral component had evidence of loosening. Eight acetabular components were revised because of loosening and wear, and one was revised because of recurrent dislocation. One focal femoral osteolytic lesion was seen. CONCLUSIONS: This femoral component afforded durable fixation at ten to twelve years after primary total hip arthroplasty. Level of Evidence: Therapeutic study, Level IV (case series [no, or historical, control group]). See Instructions to Authors for a complete description of levels of evidence.
机译:背景:很少报道全髋关节置换术不使用水泥的长期结果。本研究的目的是评估使用近端多孔涂层,等离子喷涂,直柄钛合金股骨组件进行的初次全髋关节置换术的最少十年结果。方法:回顾性分析了术后10至12年内对95例患者进行的连续105例全髋关节置换的临床和影像学结果。诊断为七十七髋(73%)的骨关节炎。根据Harris髋关节评分,并发症和大腿疼痛评估临床结果。每次随访都进行了详细的射线照相分析。进行Kaplan-Meier分析以评估股骨组件的存活。结果:Harris髋关节平均评分从术前的46分提高到术后的92分。最近一次随访时的平均疼痛评分为42分,其中83髋(79%)被评为无疼痛。仅两名患者发现大腿疼痛。在茎尖周围可见所有射线可透线。所有的髋骨都有一定程度的股骨重塑,与骨向内生长一致。没有修改股骨成分,也没有股骨成分松动的迹象。由于松动和磨损,对8个髋臼组件进行了修订,由于反复脱位,对1个进行了修订。可见一个局灶性股骨溶骨性病变。结论:该股骨部件在初次全髋关节置换术后10至12年提供了持久的固定。证据级别:治疗研究,级别IV(案例系列[无,或历史,对照组])。有关证据水平的完整说明,请参见《作者须知》。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号