首页> 外文期刊>The journal of asthma >Measurement of fractional exhaled nitric oxide by a new portable device: comparison with the standard technique.
【24h】

Measurement of fractional exhaled nitric oxide by a new portable device: comparison with the standard technique.

机译:用新型便携式设备测量呼出气中一氧化氮的含量:与标准技术进行比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: Fractional exhaled nitric oxide (FeNO) measurement is a reliable, noninvasive marker of airway inflammation. The use of portable FeNO analyzers may enable the assessment of airway inflammation in primary care. OBJECTIVE: The authors compared FeNO values obtained by a new portable device (NObreath, Bedfont, UK) to those of the standard stationary analyzer (NIOX, Aerocrine, Sweden) in a large cohort of asthmatic patients. METHODS: One hundred and fifty-four (age range: 14-83 years, forced expiratory volume in one second [FEV(1)] range: 48-134% predicted, asthma control test [ACT] range: 7-25) out of 168 recruited patients completed the study. Each patient performed at least two valid FeNO measurements at a constant flow rate of 50 ml/s on each of the two analyzers. RESULTS: A significant relationship between the FeNO values obtained by the two devices (r = .95, p < .001) was found. Altman-Bland plot confirmed this agreement. Within-patient repeatability was excellent in both devices. Intraclass correlation coefficients for NIOX and NObreath values were .925 and .967, respectively. By means of receiver operating characteristic curve analysis, the FeNO cutoff points that better identified patients with ACT >/= 20 were 15 ppb (0.84 sensitivity and 0.42 specificity) by NIOX and 25 ppb (0.53 sensitivity and 0.69 specificity) by NObreath. Easiness to use of both devices, assessed by visual analogue scale was not different. CONCLUSION: FeNO measurements obtained by the new portable FeNO analyzer are reliable because they are directly comparable with those obtained by the stationary standard device. The use of portable instruments may facilitate the FeNO measurement in primary care.
机译:背景:呼出气一氧化氮(FeNO)的测量是一种可靠,无创的气道炎症标记物。使用便携式FeNO分析仪可以评估初级保健中的气道炎症。目的:作者比较了一大批哮喘患者通过新型便携式设备(NObreath,英国Bedfont,英国)获得的FeNO值与标准固定分析仪(NIOX,Aerocrine,瑞典)获得的FeNO值。方法:154(年龄范围:14-83岁,在一秒钟内强制呼气量[FEV(1)]范围:预测的48-134%,哮喘控制测试[ACT]范围:7-25) 168名新招募的患者完成了研究。每位患者在两个分析仪上均以50 ml / s的恒定流速执行了至少两次有效的FeNO测量。结果:发现两种装置的FeNO值之间存在显着关系(r = .95,p <.001)。奥特曼·布兰德的阴谋证实了这一协议。两种设备的患者内重复性都非常好。 NIOX和NObreath值的类内相关系数分别为.925和.967。通过接收器工作特性曲线分析,通过NIOX更好地识别出ACT> / = 20的患者的FeNO截止点通过NIOX为15 ppb(灵敏度为0.84和0.42特异性),而通过NObreath则为25 ppb(灵敏度为0.53和0.69特异性)。通过视觉模拟量表评估的两种设备的易用性没有差异。结论:新型便携式FeNO分析仪获得的FeNO测量值是可靠的,因为它们可以直接与固定式标准设备获得的结果进行比较。便携式仪器的使用可能有助于初级保健中的FeNO测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号