2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) is a highly sensitive chromogenic reagent that can react with most of the transition and alkaline earth metals. The Ni(II)-5-Br-PADAP complex is more stable than other metal-5-Br-PADAP complexes. In the presence of seignette salt, ethylenediaminetetraacetic acid (EDTA) can decompose most of the 5-Br-PADAP complexes with metals except for iron, cobalt, and nickel. Cetrimonium bromide (CTMAB) as a sensitizer for the color reaction forms a ternary complex with nickel and 5-Br-PADAP with maximum absorption wavelength at 561 nm. CTMAB can significantly improve the sensitivity and selectivity of nickel determination, as well as the stability and solubility of compounds. In this study, the determination of trace nickel in natural water samples was performed by flow injection analysis. The calibration lines were established in the range of 0-200 mu g/l of nickel (n a parts per thousand yen 3), and the limit of detection was 0.093 mu g/l. The relative standard deviation was 2.55% for the determination of 25 mu g/l nickel (n a parts per thousand yen 20). The recoveries of this method ranged from 91.0 to 101% for environmental water samples. A large amount of aluminum, calcium, cadmium, copper, bicarbonate, magnesium, zinc, and iron, except for cobalt, did not interfere with the determination of nickel.
机译:2-(5-溴-2-吡啶基偶氮)-5-二乙基氨基苯酚(5-Br-PADAP)是一种高度敏感的生色试剂,可以与大多数过渡金属和碱土金属反应。 Ni(II)-5-Br-PADAP配合物比其他金属-5-Br-PADAP配合物更稳定。在存在尖峰盐的情况下,乙二胺四乙酸(EDTA)可以分解除铁,钴和镍以外的大多数5-Br-PADAP与金属的络合物。溴化铈(CTMAB)作为显色反应的敏化剂与镍和5-Br-PADAP形成三元络合物,最大吸收波长为561 nm。 CTMAB可以显着提高镍测定的灵敏度和选择性,以及化合物的稳定性和溶解性。在这项研究中,通过流动注射分析法测定了天然水样品中的痕量镍。在镍的0-200μg/ l(每千日元n 1份)的范围内建立校准线,并且检测限为0.093μg/ l。相对标准偏差为2.55%,用于测定25μg / l的镍(每千日元n的份数)。对于环境水样品,该方法的回收率在91.0%到101%之间。除钴外,大量的铝,钙,镉,铜,碳酸氢盐,镁,锌和铁不会干扰镍的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号