...
首页> 外文期刊>Journal of AOAC International >Crosslinked poly (4-vinylpyridine-ethylene glycol dimethacrylate) used for preconcentration of Cd(II) and its determination by flow injection flame atomic absorption spectrometry.
【24h】

Crosslinked poly (4-vinylpyridine-ethylene glycol dimethacrylate) used for preconcentration of Cd(II) and its determination by flow injection flame atomic absorption spectrometry.

机译:交联的聚(4-乙烯基吡啶-乙二醇二甲基丙烯酸酯),用于Cd(II)的预浓缩及其流动注射火焰原子吸收光谱法的测定。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The main purpose of this research was to synthesize crosslinked poly(4-vinylpyridine-ethylene glycol dimethacrylate) and evaluate its feasibility for highly sensitive and selective determination of Cd in water samples by using flow injection flame atomic absorption spectrometry. The crosslinked polymer, prepared by bulk polymerization, was characterized by FTIR spectrometry and scanning electron microscopy. The flow injection solid-phase method was based on preconcentration of 20.0 mL of sample through 100 mg of the polymer packed into a minicolumn at pH 8.25 using a flow rate of 6.0 mL/min, followed by elution with 1.0 M HNO3. The sample solution parameters influencing the preconcentration behavior of Cd ions, such as pH, buffer concentration, and flow rate, were simultaneously studied and optimized using a Doehlert matrix. Values of 0.10 micro g/L, 2.0-210 micro g/L, 32.3, 18/h, 9.7/min, and 0.62 mL were obtained for LOD, linear range, preconcentration factor, sample throughput, concentration efficiency, and consumption index, respectively. The effect of the presence of the inorganic cations Pb(II), U(IV), Co(II), Hg(II), Cu(II), As(III), Mg(II), Sb(III), Ni(II), Th(IV), Ba(II), and Ca(II) on the method was studied, and the preconcentration of Cd was observed to have no interference. The accuracy of the method was assessed by analysis of natural water samples using addition and recovery tests and inductively coupled plasma/MS as a reference technique, as well as by analysis of a standard reference material of trace elements in water.
机译:这项研究的主要目的是合成交联的聚(4-乙烯基吡啶-乙二醇二甲基丙烯酸酯),并通过流动注射火焰原子吸收光谱法评估其在水样品中高灵敏度和选择性测定镉的可行性。通过本体聚合制备的交联聚合物通过FTIR光谱和扫描电子显微镜表征。流动注射固相方法的基础是,通过以6.0 mL / min的流速通过pH值为8.25的微型柱中填充的100 mg聚合物对20.0 mL样品进行预浓缩,然后用1.0 M HNO 3洗脱。使用Doehlert矩阵同时研究和优化了影响Cd离子预浓缩行为的样品溶液参数,例如pH,缓冲液浓度和流速。对于LOD,线性范围,预浓缩因子,样品通量,样品通量,浓缩效率和消耗指数,获得的值为0.10 micro g / L,2.0-210 micro g / L,32.3、18 / h,9.7 / min和0.62 mL,分别。无机阳离子Pb(II),U(IV),Co(II),Hg(II),Cu(II),As(III),Mg(II),Sb(III),Ni的存在的影响研究了该方法中的(II),Th(IV),Ba(II)和Ca(II),并观察到Cd的预浓缩没有干扰。该方法的准确性通过使用添加和回收测试以及电感耦合等离子体/ MS作为参考技术对天然水样进行分析,以及通过分析水中痕量元素的标准参考物质来评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号