首页> 外文期刊>Journal of AOAC International >Quantitative Determination of Flavonoids by Column High-Performance Liquid Chromatography with Mass Spectrometry and Ultraviolet Absorption Detection in Artemisia afra and Comparative Studies with Various Species of Artemisia Plants
【24h】

Quantitative Determination of Flavonoids by Column High-Performance Liquid Chromatography with Mass Spectrometry and Ultraviolet Absorption Detection in Artemisia afra and Comparative Studies with Various Species of Artemisia Plants

机译:高效液相色谱-高效液相色谱-质谱法测定蒿中黄酮的含量及与多种蒿属植物的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

A simple and specific analytical method for the quantitative determination of flavonoids from the aerial parts of the Artemisia afra plant samples was developed. By column high-performance liquid chromatography (HPLC) with UV absorption and mass spectrometry (MS) detection, separation was achieved on a reversed-phase octadecylsilyl (C18) column with water, methanol, and acetonitrile, all containing 0.1% acetic acid, as the mobile phase. These methods were used to analyze various species of Artemisia plant samples. The wavelength used for quantification of flavonoids with the diode array detector was 335 nm. The limits of detection (LOD) by HPLC/MS were found to be 7.5, 7.5,10, 2.0, and 2.0 ng/mL; and by LC-UV the LODs were 500, 500, 500, 300, and 300 ng/mL for apigenin, chrysoeriol, tamarixetin, acacetin, and genkwanin, respectively. The HPLC/MS method was found to be 50-150 times more sensitive than the HPLC-UV method. HPLC/MS coupled with an electrospray ionization interface is described for the identification and quantification of flavonoids in various plant samples. This method involved the use of the [M+H](+) ions of the compounds at mass-to-charge ratio of 1.0606, 301.0712, 317.0661, 285.0763, and 285.0763 (calculated mass), respectively, in the positive ion mode with extractive ion monitoring.
机译:建立了一种简单而特定的分析方法,用于从蒿属植物样品的地上部分定量测定类黄酮。通过具有紫外吸收和质谱(MS)检测功能的高效液相色谱(HPLC)色谱柱,在反相十八烷基甲硅烷基(C18)色谱柱上用水,甲醇和乙腈(均含0.1%乙酸)进行分离流动相。这些方法用于分析不同种类的蒿植物样品。用二极管阵列检测器定量黄酮的波长为335 nm。 HPLC / MS的检出限(LOD)为7.5、7.5、10、2.0和2.0 ng / mL; LC-UV检测的芹菜素,金葱酚,他马西汀,阿沙西汀和Genkwanin的LOD分别为500、500、500、300和300 ng / mL。发现HPLC / MS方法的灵敏度是HPLC-UV方法的50-150倍。高效液相色谱/质谱联用电喷雾电离接口被描述用于鉴定和定量各种植物样品中的类黄酮。该方法涉及在正离子模式下以质荷比分别为1.0606、301.0712、317.0661、285.0763和285.0763(计算质量)使用化合物的[M + H](+)离子。萃取离子监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号