Method for the Rapid Determination of Protein in Meats Using the CEM Sprint (TM) Protein Analyzer: Collaborative Study

机译:使用CEM Sprint(TM)蛋白质分析仪快速测定肉类蛋白质的方法:协作研究

获取原文
获取原文并翻译 | 示例
           

摘要

A collaborative study was conducted to determine the protein content of raw and processed meat products by a protein-tagging and colorimetric technique. Meat products were prepared following AOAC Official Method(SM) 983.18 and analyzed using CEM Corporation's Sprint Rapid Protein Analyzer. Sprint provides protein results by combining an accurately weighed test portion with a known amount of dye-binding agent. The dye-binding agent binds with the lysine, histidine, and arginine, as well as the n-terminus of the proteins commonly found in raw meat and processed meat products. Results are displayed and reported by the Sprint as a percentage (g/100 g) of protein. Ten blind duplicate study samples were sent to 10 collaborating laboratories in the United States. The within-laboratory (repeatability) relative standard deviation (RSDr) ranged from 0.91 to 3.04%, and between-laboratories (reproducibility) relative standard deviation (RSDR) ranged from 1.50 to 3.41% for protein. The method is recommended for Official First Action.
机译:通过蛋白质标记和比色技术进行了一项合作研究,以确定生肉和加工肉制品的蛋白质含量。肉类产品是根据AOAC Official Method(SM)983.18制备的,并使用CEM Corporation的Sprint快速蛋白质分析仪进行分析。 Sprint通过将精确称重的测试部分与已知量的染料结合剂结合在一起来提供蛋白质结果。染料结合剂与赖氨酸,组氨酸和精氨酸以及生肉和加工肉制品中常见的蛋白质的n末端结合。结果由Sprint显示并报告为蛋白质的百分比(g / 100 g)。将十个盲目的重复研究样本发送到美国的十个合作实验室。蛋白质的实验室内(重复性)相对标准偏差(RSDr)为0.91至3.04%,实验室间(可重复性)相对标准偏差(RSDR)为1.50至3.41%。建议将该方法用于“官方第一个行动”。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号