Enzyme-linked immunosorbent assay based on a polyclonal antibody for the detection of the insecticide fenitrothion. Evaluation of antiserum and application to the analysis of water samples

机译:基于多克隆抗体的酶联免疫吸附试验,用于检测杀虫剂杀nitro硫磷。抗血清评估及其在水样分析中的应用

获取原文
获取原文并翻译 | 示例
       

摘要

For development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the organophosphorus insecticide fenitrothion, the specificity of the antiserum R-3 generated with the bifunctional hapten, LysMNPA (2-[[[(3-methyl-4-nitrophenyl)oxy]methylcarbonyl]amino]-6-(2,4-dinitrophen yl)aminohexanoic acid) and the application to the residual analysis of some water samples were evaluated. At optimized ELISA conditiond, the quantitative working range was from 1 to 39 ng/mL with a limit of detection of 0.3 ng/mL and an IC50 value of 6 ng/mL. Cross-reactivity to structurally similar organophosphorus compounds and related chemicals was determined. The antiserum R-3 showed significant cross-reactivity with fenitrooxon and 3-methyl-4-nitrophenol, which have a 3-methy-4-nitrophenoxy group as common structures, but showed relatively low cross-reactivity with other compounds. Each water sample (river water, tap water, purified water, and bottled water) had a matrix effect and was investigated by adding Tween 20 in the assay buffer. These four kinds of water samples were fortified with fenitrothion at several concentration levels and were directly analyzed with only dilution with an equal volume of antiserum solution. The mean recovery was 105.9%, and the mean coefficient of variation was 10.9%. The results suggested that the developed ELISA would be very suitable for a preliminary screening for fenitrothion in water samples at such low levels. [References: 38]
机译:为开发有机磷杀虫剂杀fe硫磷的间接竞争性酶联免疫吸附测定(ELISA),双功能半抗原LysMNPA(2-[[[((3-甲基-4-硝基苯基)评估了[氧]甲基羰基]氨基] -6-(2,4-二硝基苯基)氨基己酸的含量及其在某些水样残留分析中的应用。在优化的ELISA条件下,定量工作范围为1至39 ng / mL,检出限为0.3 ng / mL,IC50值为6 ng / mL。确定了与结构相似的有机磷化合物和相关化学物质的交叉反应性。抗血清R-3与Fenitrooxon和3-甲基-4-硝基苯酚具有显着的交叉反应性,后者具有3-甲基-4-硝基苯氧基作为共同结构,但与其他化合物的交叉反应性相对较低。每种水样品(河流水,自来水,纯净水和瓶装水)都有基质作用,可以通过在检测缓冲液中添加Tween 20进行研究。这四种水样品都在不同浓度下用杀nitro硫磷进行了强化,并且仅用等体积的抗血清溶液稀释即可直接进行分析。平均回收率为105.9%,平均变异系数为10.9%。结果表明,开发的ELISA非常适合于如此低含量的水中样品中杀nitro硫酮的初步筛选。 [参考:38]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号