首页> 外文期刊>Journal of analytical chemistry >Electrochemical reduction of selenium on a silver electrode and its determination in river water
【24h】

Electrochemical reduction of selenium on a silver electrode and its determination in river water

机译:银电极上硒的电化学还原及其在河水中的测定

获取原文
获取原文并翻译 | 示例

摘要

A new, simple, and fast method is described for determining selenium based on a silver wire electrode flow-through voltammetric detector. A comparison was done between the sensitivity of disk silver, mercury-modified glassy carbon, and mercury-modified gold electrodes. The response of the flow-through voltammetric detector was evaluated with respect to each electrode's operating potential and pH in direct current mode. The limit of detection (3s) for Se(IV) was below 0.01 mg/L. The flow-through system does not need deposition times and the organic matter does not need to be removed before determining selenium in river water.
机译:描述了一种基于银线电极流通伏安法测定硒的新的,简单而快速的方法。在圆盘银,汞改性玻璃碳和汞改性金电极的灵敏度之间进行了比较。针对直流模式下每个电极的工作电势和pH值,评估了流通伏安检测器的响应。 Se(IV)的检出限(3s)低于0.01 mg / L。在确定河水中的硒之前,流通系统不需要沉积时间,也不需要除去有机物。