A simple, rapid and reliable method was developed for the determination of copper, nickel, iron and lead in fresh and used lubricating oil samples by flame atomic absorption spectrophotometry (FAAS). In the present study, a mixture of organic solvents containing propionic acid and iso-butylmethyl ketone (1 : 1) was used to extract the metals from lubricating oil samples followed by FAAS analysis. Aqueous standard solutions can be easily employed with the proposed mixed solvent system instead of organometallic standards. The analytical results obtained by employing the proposed solvent extraction system were found to be in good agreement with the results for aqueous media obtained after the destruction of oil samples matrix. Percentage recovery studies showed 88-98% for Cu, 92-95% for Fe, 96-106% for Ni and 84-100% for Pb with relative standard deviation of 2-6%. The developed method was effectively applied to routine determination of Cu, Ni, Fe, and Pb in lubricating oil samples.
机译:建立了一种简单,快速,可靠的方法,通过火焰原子吸收分光光度法(FAAS)测定新鲜和使用过的润滑油样品中的铜,镍,铁和铅。在本研究中,使用含有丙酸和异丁基甲基酮(1:1)的有机溶剂混合物从润滑油样品中提取金属,然后进行FAAS分析。水溶液标准溶液可以轻松地与建议的混合溶剂体系一起使用,而不是有机金属标准溶液。发现采用建议的溶剂萃取系统获得的分析结果与破坏油样基质后获得的水性介质的结果非常吻合。百分比回收率研究表明,铜为88-98%,铁为92-95%,镍为96-106%,铅为84-100%,相对标准偏差为2.6%。所开发的方法有效地应用于了润滑油样品中铜,镍,铁和铅的常规测定。