首页> 外文期刊>Journal of anesthesia >Subdural hematoma following labor analgesia utilizing an intrathecal catheter
【24h】

Subdural hematoma following labor analgesia utilizing an intrathecal catheter

机译:分娩镇痛后使用鞘内导管进行硬膜下血肿

获取原文
获取原文并翻译 | 示例
           

摘要

To the Editor: We report a subdural hematoma following repeated neuraxial analgesia during labor. A healthy parturient presented with an unremarkable preanesthetic examination. At L3-L4, an 18-gauge Tuohy was advanced until a depth of 4 cm. Free-flowing cerebral spinal fluid (CSF) confirmed accidental dural puncture. A 20-gauge catheter was advanced 4 cm into the intrathecal space (IT) and secured at 8 cm at the skin. One milliliter bupivacaine 0.25 % with sufentanil 5 mug preceded infusion of bupivacaine 0.0625 % with fentanyl 1.5 mug/ml and epinephrine 1:700,000 at 2 ml/ h. Four hours later, analgesia became less potent.
机译:致编辑:我们报告了在分娩过程中反复进行神经支配镇痛后的硬膜下血肿。健康分娩者,麻醉前检查无异常。在L3-L4处,推进了18号的Tuohy,直到深度达到4 cm。自由流动的脑脊髓液(CSF)证实了意外的硬膜穿刺。将20号导管插入鞘内间隙(IT)4厘米,并固定在皮肤的8厘米处。在以2 ml / h的速度输注0.0625%的布比卡因和fentanyl 1.5杯/毫升和肾上腺素1:700,000的情况下,先用0.25%的舒芬太尼5杯的布比卡因和0.0625%的布比卡因。四小时后,镇痛作用减弱。