首页> 外文期刊>Journal of Andrology >Optimization of a filter-lysis protocol to purify rat testicular homogenates for automated spermatid counting.
【24h】

Optimization of a filter-lysis protocol to purify rat testicular homogenates for automated spermatid counting.

机译:优化过滤器裂解方案以纯化大鼠睾丸匀浆,以进行自动精子计数。

获取原文
获取原文并翻译 | 示例
           

摘要

Quantifying testicular homogenization-resistant spermatid heads (HRSH) is a powerful indicator of spermatogenesis. These counts have traditionally been performed manually using a hemocytometer, but this method can be time consuming and biased. We aimed to develop a protocol to reduce debris for the application of automated counting, which would allow for efficient and unbiased quantification of rat HRSH. We developed a filter-lysis protocol that effectively removes debris from rat testicular homogenates. After filtering and lysing the homogenates, we found no statistical differences between manual (classic and filter-lysis) and automated (filter-lysis) counts using 1-way analysis of variance with Bonferroni's multiple comparison test. In addition, Pearson's correlation coefficients were calculated to compare the counting methods, and there was a strong correlation between the classic manual counts and the filter-lysis manual (r = 0.85, P = .002) and the filter-lysis automated (r = 0.89, P = .0005) counts. We also tested the utility of the automated method in a low-dose exposure model known to decrease HRSH. Adult Fischer 344 rats exposed to 0.33% 2,5-hexanedione in the drinking water for 12 weeks demonstrated decreased body (P = .02) and testes (P = .002) weights. In addition, there was a significant reduction in the number of HRSH per testis (P = .002) when compared to controls. A filterlysis protocol was optimized to purify rat testicular homogenates for automated HRSH counts. Automated counting systems yield unbiased data and can be applied to detect changes in the testis after low-dose toxicant exposure.
机译:量化睾丸抗均质性精子头(HRSH)是精子发生的有力指标。传统上,这些计数是使用血细胞计数器手动进行的,但是这种方法既费时又有偏差。我们旨在开发一种减少碎片的方案,以减少自动计数的应用,从而实现对大鼠HRSH的高效无偏定量。我们开发了一种过滤器溶解方案,可有效去除大鼠睾丸匀浆中的碎屑。在对匀浆物进行过滤和溶解后,我们发现使用Bonferroni多重比较检验进行方差单向分析时,手动(经典和过滤器裂解)计数与自动(过滤器裂解)计数之间无统计学差异。此外,计算了Pearson的相关系数以比较计数方法,并且经典手动计数与过滤器溶解手册(r = 0.85,P = .002)和自动过滤器溶解(r = 0.89,P = .0005)计数。我们还在已知降低HRSH的低剂量暴露模型中测试了自动化方法的实用性。成年Fischer 344大鼠在饮用水中暴露于0.33%的2,5-己二酮12周后,体重(P = .02)和睾丸(P = .002)减少。此外,与对照组相比,每个睾丸的HRSH数量显着减少(P = .002)。优化了滤膜溶解方案以纯化大鼠睾丸匀浆以进行自动HRSH计数。自动化计数系统可产生无偏数据,可用于检测低剂量毒物暴露后睾丸的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号