...
首页> 外文期刊>Journal of Analytical Toxicology >Simultaneous analysis of 22 antiepileptic drugs in postmortem blood, serum and plasma using LC-MS-MS with a focus on their role in forensic cases.
【24h】

Simultaneous analysis of 22 antiepileptic drugs in postmortem blood, serum and plasma using LC-MS-MS with a focus on their role in forensic cases.

机译:使用LC-MS-MS同时分析死后血液,血清和血浆中的22种抗癫痫药,重点是其在法医案例中的作用。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In recent years, there has been a growth in reports of antiepileptic drugs (AEDs) being misused on their own or in combination with other drugs of abuse in a variety of toxicological case types such as drug abuse, suicide, overdose and drug facilitated crime. To our knowledge, there are no simultaneous quantification methods for the analysis of the most commonly encountered AEDs in postmortem whole blood and clinical plasma/serum samples at the same time. A simple, accurate and cost-effective liquid chromatography-tandem mass spectrometric (LC-MS-MS) method has been developed and validated for the simultaneous quantification of carbamazepine (CBZ) and its metabolite CBZ-10,11-epoxide, eslicarbazepine acetate, oxcarbazepine and S-licarbazepine as a metabolite, gabapentin, lacosamide, lamotrigine, levetiracetam, pregabalin, phenobarbital, phenytoin and its metabolite 5-(p-hydroxyphenyl)-5-phenylhydantoin, retigabine (ezogabine) and its metabolite N-acetyl retigabine, rufinamide, stiripentol, topiramate, tiagabine, valproic acid, vigabatrin and zonisamide in postmortem whole blood, serum and plasma which would be suitable for routine forensic toxicological analysis and therapeutic drug monitoring. All AEDs were detected and quantified within 17 min without endogenous interferences. The correlation coefficient (R(2)) was >0.995 for all AEDs with accuracy ranging from 90 to 113% and precision <13% for all analytes. The recovery ranged from 70 to 98%. No carryover was observed in a blank control injected after the highest standard and the matrix effect was acceptable and ranged from 90 to 120%. The method has been successfully verified using authentic case samples that had previously been quantified using different methods.
机译:近年来,关于在各种毒理学案例类型中滥用抗癫痫药物(AED)或与其他滥用药物结合使用的报告不断增多,例如药物滥用,自杀,过量和毒品促成犯罪。据我们所知,没有同时进行定量的方法来同时分析死后全血和临床血浆/血清样品中最常见的AED。已开发出一种简单,准确且经济高效的液相色谱-串联质谱(LC-MS-MS)方法,并已验证该方法可同时定量卡马西平(CBZ)及其代谢产物CBZ-10,11-环氧化物,依斯卡西平醋酸盐,奥卡西平和S-卡巴西平的代谢产物,加巴喷丁,拉考酰胺,拉莫三嗪,左乙拉西坦,普瑞巴林,苯巴比妥,苯妥英钠及其代谢物5-(对羟基苯基)-5-苯基乙内啡肽,瑞替加滨(ezogabine)及其代谢物N-乙酰基芦丁糖胺验尸全血,血清和血浆中的苯丙胺醇,托吡酯,托吡酯,替加滨,丙戊酸,维加巴汀和唑尼沙胺,适用于常规法医毒理分析和治疗药物监测。在没有内源干扰的情况下,在17分钟内检测并定量了所有AED。所有AED的相关系数(R(2))> 0.995,所有分析物的准确度范围为90%至113%,准确度<13%。回收率在70%至98%之间。在最高标准后注射的空白对照中未观察到残留,基质效果可接受,范围为90%至120%。该方法已使用之前已使用不同方法进行定量的真实病例样本成功验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号