首页> 外文期刊>Journal of Analytical Toxicology >Field-test of a date-rape drug detection device.
【24h】

Field-test of a date-rape drug detection device.

机译:日期强奸药物检测设备的现场测试。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Drink Safe Technology Version 1.2 is an inexpensive color-change reagent test marketed internationally for use by consumers in settings such as a night club to detect potentially incapacitating concentrations of gamma-hydroxybutyric acid (GHB) and ketamine in beverages. The objective of this study was to compare product performance in the laboratory and performance in the hands of consumers in the field. Product performance in the laboratory adhered to the protocol defined by the manufacturer. Product performance in the hands of consumers in field settings allowed browsing participants to pipette an aliquot of their own drinks into randomly coded vials containing authentic drugs, or pure water, so as to yield the same concentrations of GHB or ketamine specified in the manufacturer-defined protocol, or blanks. Consumers were to proceed according to the directions printed on the product, and to record their results on a card with a code corresponding with the vial to which they had added an aliquot of their beverage. Diagnostic performance was calculated using two-way analysis. In the laboratory, Drink Safe Technology Version 1.2 reliably detected GHB and ketamine at concentrations specified by the manufacturer's protocol. The reactive color change denoting a positive test for GHB was rapid, but a positive test for ketamine required substantially more time to resolve. Nonetheless, test accuracy following the manufacturer's protocol in the laboratory was 100%. In the field, based on 101 paired-test results recorded by consumers, the test efficiency was 65.1%, sensitivity 50%, and specificity 91.6%. The product performed much better in the laboratory than it did in the hand of consumers in the field. There seems to be considerable potential for consumers to misinterpret a test result. The potential for consumers to record a false-negative test result for a spiked drink is cause for concern.
机译:饮料安全技术1.2版是一种廉价的变色试剂测试,已在国际上出售,供消费者在夜总会等场所使用,以检测饮料中潜在丧失功能的γ-羟基丁酸(GHB)和氯胺酮的浓度。这项研究的目的是比较实验室中的产品性能和现场消费者手中的性能。实验室中的产品性能符合制造商定义的协议。在现场设置中,消费者手中的产品性能使浏览的参与者可以将自己的饮料等分试样吸取到装有真实药物或纯净水的随机编码小瓶中,以产生与制造商定义的浓度相同的GHB或氯胺酮协议或空白。消费者应按照产品上印刷的说明进行操作,并将结果记录在卡片上,卡片上的代码与他们向饮料中添加了等分试样的小瓶相对应。使用双向分析计算诊断性能。在实验室中,Drink Safe Technology版本1.2能够可靠地检测出制造商规程规定的浓度的GHB和氯胺酮。表示GHB呈阳性反应的反应性颜色变化迅速,但氯胺酮呈阳性反应需要大量时间才能解决。但是,按照制造商的协议在实验室中进行测试的准确性为100%。在现场,根据消费者记录的101个配对测试结果,测试效率为65.1%,灵敏度为50%,特异性为91.6%。该产品在实验室中的表现比在现场消费者手中的表现要好得多。消费者似乎很可能会误解测试结果。消费者有可能记录加标饮料的假阴性测试结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号