comparative study of measurements of atmospheric gaseous nitric acid and ammonia and particulate nitrate and ammonium concentrations was conducted using various types of filter packs and denuder systems.Some of the filter packs use are recommended by the European Monitouing and Evaluation Programme(EMEP) and are widely used in the Nordic Countries and elsewhere in Europe.In addition,nitrogen dioxide was measured using iodide-impregnated sintered glass filters and the differential optical absorption spectrometer method.Particulate nitrate and ammonium concentrations were measured with two different size segregating samplers:a Berner low-jpressure impactor and a virtual impactor The weather conditions were most of the time cool and humid.The agreement between different measurements was goodfor most species,but poor for gaseous ammonia.The virtual impactor collected on average 17% more nitrate than the denuder systems,24%more than filter packs and 37%more than the Berner low-pressure impactor.The nitrate discrepancy is believed to be due to inefficient coarse particle transport into the denuder systems,fine particle nitrate evaporation in the fileter packs and Berner low-pressure impactor.The nitrate discrepancy is believed to be due to inefficient coarse particle transport into the denuder systems,fine particle nitrate evaporation in the fileter packs and Berner low-pressure impactor and,to a lesser extent,possible collection of nitric acid by the virtual imapactor.The denuder systems did not collect particles larger than about 5.6#mu#m equivalent aerodynamic diameter efficiently.Interferences were observed on the nitric acid measurements determined by a NaOH coated denuder.NaCI coated denuders seemed to operate well in this study since interferences were not observed.directC 1998 Elsvier Science Ltd.All rights reserved
机译:使用各种类型的滤嘴组件和剥蚀仪系统对大气中的气态硝酸和氨以及硝酸盐和铵盐的浓度进行了比较研究。欧洲滤镜和评估计划(EMEP)推荐使用某些滤嘴组件,并且该滤嘴组件广泛在北欧国家和欧洲其他地区也使用过。此外,二氧化氮使用碘化物浸渍的烧结玻璃滤光片和差示光吸收光谱仪方法进行测量。硝酸盐和铵盐的浓度通过两种不同尺寸的分离采样器进行测量:Berner low- j压力撞击器和虚拟撞击器天气大部分时间都是凉爽和潮湿的。不同测量值之间的一致性对大多数物种来说是好的,但对于气态氨来说却很差。虚拟撞击器收集的硝酸盐平均比剥蚀器系统多17%24比过滤器包多%,比伯纳低压impa多37%硝酸盐差异被认为是由于粗粒向剥蚀系统的传输效率低,细颗粒硝酸盐在装填器包装和Berner低压冲击器中的蒸发所致。硝酸盐差异被认为是由于粗粒向设备的传输效率低所致。剥蚀器系统,过滤器包装和Berner低压冲击器中的细颗粒硝酸盐蒸发,并且在较小程度上可能由虚拟imapactor收集硝酸。剥蚀器系统不会收集大于5.6#μ#m当量的颗粒DirectC 1998 Elsvier Science Ltd.保留所有权利。有效的空气动力学直径。观察到由NaOH涂层的剥蚀仪测定的硝酸干扰。由于未观察到干扰,NaCl涂层的剥蚀剂在本研究中似乎运行良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号