首页> 外文期刊>Japanese Journal of Ophthalmology >Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery
【24h】

Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery

机译:角膜准分子激光手术后用于眼内晶状体功率计算的光线跟踪软件

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the accuracy of intraocular lens (IOL) power calculations using ray tracing software in eyes after myopic laser in situ keratomileusis (LASIK). Methods: Twenty-four eyes of 17 cataract patients who underwent phacoemulsification and IOL implantation after myopic LASIK were analyzed retrospectively. The IOL power calculation was performed using OKULIX ray tracing software. The axial length was measured using the IOLMaster and keratometry data using TMS2N. The accuracy of the IOL power calculation using OKULIX was compared with those using the Camellin-Calossi, Shammas-PL, Haigis-L formulas and the double-K SRK/T formula using 43.5 diopters (D) for the Kpre. Results: The mean values of the arithmetic and absolute prediction errors were 0.63 ± 0.85 and 0.80 ± 0.68 D, respectively. The arithmetic prediction error by OKULIX was a significant hyperopic shift of the distribution of the postoperative refractive errors compared to the Camellin-Calossi, Shammas-PL and Haigis-L formulas (P < 0.05), and the absolute prediction error showed no significant difference with other formulas. The prediction errors using OKULIX were within ±0.5 D in 10 eyes (41.7 %) and within ±1.0 D in 18 eyes (75.0 %). The percentages of eyes within ±1.0 D using OKULIX were comparable to those obtained using the Camellin-Calossi, the Shammas-PL formulas and the double-K SRK/T formula using 43.5 D for the Kpre, and significantly (P < 0.05) higher than that obtained using the Haigis-L formula. Conclusions: IOL power calculations using OKULIX provided predictable outcomes in eyes that had undergone a previous myopic LASIK.
机译:目的:使用近视激光原位角膜磨镶术(LASIK)后,使用射线追踪软件评估眼内晶状体(IOL)屈光度的准确性。方法:回顾性分析17例近视LASIK术后行白内障超声乳化加人工晶体植入术的白内障患者的24只眼。使用OKULIX光线跟踪软件执行IOL功率计算。使用IOLMaster测量轴向长度,使用TMS2N测量角膜测量数据。将使用OKULIX的IOL功率计算的精度与使用Camellin-Calossi,Shammas-PL,Haigis-L公式和使用K的43.5屈光度(D)的double-K SRK / T公式的精度进行了比较。结果:算术误差和绝对预测误差的平均值分别为0.63±0.85和0.80±0.68D。与Camellin-Calossi,Shammas-PL和Haigis-L公式相比,OKULIX的算术预测误差是术后屈光误差分布的显着远视变化(P <0.05),并且绝对预测误差与其他公式。使用OKULIX的预测误差在10只眼中在±0.5 D之内(41.7%),在18只眼中在±1.0 D之内(75.0%)。使用OKULIX在±1.0 D之内的眼睛百分比与使用Camellin-Calossi,Shammas-PL公式和对Kpre使用43.5 D的double-K SRK / T公式获得的眼睛百分比相当,并且显着更高(P <0.05)比使用Haigis-L公式获得的结果要高。结论:使用OKULIX进行的IOL屈光力计算可为先前经历过近视LASIK的眼睛提供可预测的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号