首页> 外文期刊>Japanese Journal of Ophthalmology >Scanning laser tomography to evaluate optic discs of normal eyes.
【24h】

Scanning laser tomography to evaluate optic discs of normal eyes.

机译:扫描激光断层扫描以评估正常眼睛的视盘。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To investigate the effects of age, eye refraction, and disc area on topographic parameters of the optic nerve head in normal volunteers, using the Heidelberg Retina Tomograph. METHODS: Seventy-seven eyes of 77 normal volunteers were examined by scanning laser tomography. The topographic parameters analyzed were disc area, cup area, cup/disc area ratio, rim area, cup volume, rim volume, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness (MnRNFLT), and retinal nerve fiber layer (RNFL) cross-section area. The effect of age, refraction, and disc area on each parameter was analyzed by the multiple linear regression model. RESULTS: Significant declines in MnRNFLT and RNFL cross-section area were found with increasing age (P < .05). The mean cup depth and maximum cup depth were significantly deeper in myopic subjects (P < .05). Large discs had large cup area, cup/disc area ratio, rim area, cup volume, mean cup depth, cup shape measure (P < .01), and maximum cup depth (P < .05). The MnRNFLT was smaller in large discs (P < .01). Rim volume was unaffected by age, refraction, or disc area. CONCLUSIONS: The age, refraction, and disc area were related to several optic disc parameters obtained by the Heidelberg Retina Tomograph. Because of these relationships, care should be taken to analyze the appearance of the optic disc on the basis of these parameters in patients with glaucoma or other diseases. Rim volume appears to be a good parameter for evaluating the optic disc without considering age, refraction, or disc area.
机译:目的:使用海德堡视网膜断层扫描仪研究年龄,眼屈光度和椎间盘面积对正常志愿者视神经乳头形貌参数的影响。方法:对77名正常志愿者的77只眼睛进行了扫描激光层析成像检查。分析的地形参数是椎间盘面积,杯面积,杯/盘面积比,轮辋面积,杯体积,轮辋体积,平均杯深度,最大杯深度,杯形状度量,高度变化轮廓,平均视网膜神经纤维层厚度(MnRNFLT) )和视网膜神经纤维层(RNFL)的横截面积。通过多元线性回归模型分析了年龄,屈光度和椎间盘面积对每个参数的影响。结果:随着年龄的增长,发现MnRNFLT和RNFL横截面积显着下降(P <.05)。在近视受试者中,平均杯深度和最大杯深度明显更深(P <.05)。大圆盘具有较大的杯子面积,杯子/圆盘面积比,轮辋面积,杯子体积,平均杯子深度,杯子形状尺寸(P <.01)和最大杯子深度(P <.05)。在大圆盘中,MnRNFLT较小(P <.01)。轮辋的体积不受年龄,屈光度或椎间盘面积的影响。结论:年龄,屈光度和椎间盘面积与海德堡视网膜断层扫描仪获得的多个视盘参数有关。由于这些关系,在青光眼或其他疾病患者中,应根据这些参数来分析视盘的外观。轮辋体积似乎是评估视盘的好参数,而无需考虑使用年限,屈光度或视盘面积。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号