首页> 外文期刊>Japanese journal of radiology >Utility of contrast-enhanced ultrasonography for qualitative imaging of atherosclerosis in Watanabe heritable hyperlipidemic rabbits: initial experimental study.
【24h】

Utility of contrast-enhanced ultrasonography for qualitative imaging of atherosclerosis in Watanabe heritable hyperlipidemic rabbits: initial experimental study.

机译:超声造影对渡边可遗传高脂血症兔动脉粥样硬化定性成像的实用性:初步实验研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Using Watanabe heritable hyperlipidemic (WHHL) rabbits, we investigated the ability of ultrasonography (US) to detect contrast enhancement of atherosclerotic lesions after intravenous injection of a microbubble contrast agent (MB) and confirmed the localization of MB in the lesion by transmission electron microscopy (TEM). MATERIALS AND METHODS: The abdominal aortic wall of six WHHL rabbits was observed for 20 min after MB delivery. To evaluate contrast enhancement, a region of interest (ROI) was set in the intima-media complex (IMC) and the aortic lumen. The average image brightness of the ROI was recorded as the echogenicity at each time point. Differences at each time point were analyzed by analysis of variance and the t-test. Histological analysis was performed after US observation. RESULTS: The echogenicity of the IMC was 8.48 +/- 3.01 before and 10.96 +/- 7.88, 32.42 +/- 12.79, 79, 17.73 +/- 9.118, and 31.18 +/- 13.35, respectively, at 0.5, 2, 5, 10, and 20 min after MB injection. The echogenicity of the vessel lumen was 1.16 +/- 1.57, 64.21 +/- 11.52, 53.55 9.81, 13.32 +/- 9.78, 2.63 +/- 1.45, and 3.66 +/- 3.01 at the corresponding time points. At 20 min after injection, the echogenicity of the IMC was significantly higher than before or 0.5 min after injection. The distribution of MB inside macrophages in atherosclerotic plaques could not be confirmed by TEM. CONCLUSION: Ultrasonography was able to detect contrast enhancement of the IMC at 10 and 20 min after injection of MB.
机译:目的:使用渡边遗传性高脂血症(WHHL)兔,我们调查了超声(US)检测静脉注射微泡造影剂(MB)后动脉粥样硬化病变的造影增强能力,并通过透射电子证实了MB在病变中的定位显微镜(TEM)。材料与方法:MB递送后20分钟观察六只WHHL兔的腹主动脉壁。为了评估造影剂的增强效果,在内膜-中膜复合物(IMC)和主动脉腔中设置了感兴趣区域(ROI)。 ROI的平均图像亮度记录为每个时间点的回声性。通过方差分析和t检验分析每个时间点的差异。在美国观察后进行组织学分析。结果:在0.5、2、5和5时,IMC的回声原分别为8.48 +/- 3.01和10.96 +/- 7.88、32.42 +/- 12.79、79、17.73 +/- 9.118和31.18 +/- 13.35。 MB注射后10分钟和20分钟在相应的时间点,血管腔的回声性为1.16 +/- 1.57、64.21 +/- 11.52、53.559.81、13.32 +/- 9.78、2.63 +/- 1.45和3.66 +/- 3.01。注射后20分钟,IMC的回声性显着高于注射前或注射后0.5分钟。透射电镜无法确定动脉粥样硬化斑块中巨噬细胞内MB的分布。结论:超声检查能够在注射MB后10和20分钟检测到IMC的对比度增强。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号