首页> 外文期刊>JACC. Cardiovascular interventions >Angiographic geometric changes of the lumen arterial wall after bioresorbable vascular scaffolds and metallic platform stents at 1-year follow-up.
【24h】

Angiographic geometric changes of the lumen arterial wall after bioresorbable vascular scaffolds and metallic platform stents at 1-year follow-up.

机译:在1年的随访中,生物可吸收的血管支架和金属平台支架置入后,管腔动脉壁的血管造影几何变化。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: The aim of this study was to compare the angiographic changes in coronary geometry of the bioresorbable vascular scaffolds (BVS) and metallic platform stent (MPS) between baseline and follow-up. BACKGROUND: Coronary geometry changes after stenting might result in wall shear stress changes and adverse events. The BVS have better conformability, compared with MPS, but still modify artery geometry. It is uncertain whether the BVS resorption can restore the coronary anatomical configuration at midterm follow-up. METHODS: All patients of the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions) and SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions) trials treated with a single 3.0 x 18 mm device and imaged at baseline and 6- to 12-month follow-up were eligible. Coronary geometry changes were assessed with quantitative angiography as changes in curvature and angulation. Curvature and angulation changes between systole and diastole were investigated to assess hinging movements of the coronary artery. RESULTS: One hundred sixty-one patients (86 BVS, and 75 MPS) were included. Baseline angiographic characteristics were similar. From post-implantation to follow-up, curvature increased 8.4% (p < 0.01) with BVS and decreased 1.9% (p = 0.54) with MPS; p = 0.01. Angulation increased 11.3% with BVS (p < 0.01) and 3.8% with MPS (p = 0.01); p < 0.01. From pre-implantation to follow-up, BVS decreased 3.4% the artery curvature (p = 0.05) and 3.9% the artery angulation (p = 0.16), whereas MPS presented with 26.1% decrease in curvature (p < 0.01) and 26.9% decrease in angulation (p < 0.01), being larger with MPS (p < 0.01, both). Hinging movements in curvature from pre-implantation to follow-up decreased 19.7% with BVS and 39.0% with MPS (p = 0.27) and decreased 3.9% with BVS and 26.9% with MPS in angulation (p < 0.01). CONCLUSIONS: At midterm follow-up, the BVS tended to restore the coronary configuration and the systo-diastolic movements to those seen before implantation. The coronary geometry remained similar to that seen at after implantation with MPS. (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System [BVS EECSS] in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00856856).
机译:目的:本研究的目的是比较基线和随访之间生物可吸收性血管支架(BVS)和金属平台支架(MPS)的冠状动脉血管造影变化。背景:置入支架后冠状动脉几何形状的改变可能会导致壁切应力的改变和不良事件。与MPS相比,BVS具有更好的顺应性,但仍然可以改变动脉的几何形状。尚不确定在中期随访中BVS吸收是否能恢复冠状动脉解剖结构。方法:所有ABSORB患者(生物可吸收的依维莫司洗脱冠状动脉支架系统[BVS EECSS]治疗从头开始的原发性冠状动脉病变的临床评估)和SPIRIT(XIENCE V依维莫司洗脱冠状动脉支架的临床评估)系统采用单一3.0 x 18 mm装置治疗并在基线和6到12个月的随访中进行影像学检查的de Novo天然冠状动脉病变患者的系统。冠状动脉几何变化通过定量血管造影评估为曲率和角度的变化。研究了收缩和舒张之间的曲率和角度变化,以评估冠状动脉的铰接运动。结果:共纳入161例患者(86例BVS和75例MPS)。基线血管造影特征相似。从植入后到随访,BVS曲率增加8.4%(p <0.01),MPS曲率减少1.9%(p = 0.54)。 p = 0.01。 BVS的角度增加了11.3%(p <0.01),MPS的角度增加了3.8%(p = 0.01); p <0.01。从植入前到随访,BVS的曲率下降了3.4%(p = 0.05)和3.9%(p = 0.16),而MPS的曲率下降了26.1%(p <0.01)和26.9%角度减少(p <0.01),而MPS则更大(p <0.01,两者)。从植入前到随访,曲度的铰接运动在BVS中降低了19.7%,在MPS中降低了39.0%(p = 0.27),在BVS中,MPS降低了3.9%(2%)(p <0.01)。结论:在中期随访中,BVS倾向于使冠状结构和收缩舒张运动恢复到植入前所见的状态。冠状动脉的几何形状与MPS植入后的相似。 (生物可吸收的依维莫司洗脱冠状动脉支架系统[BVS EECSS]在从头开始的天然冠状动脉病变患者的治疗中的临床评估; NCT00856856)。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号