首页> 外文期刊>Drug development and industrial pharmacy >A strategy for reducing particulate contamination on opening glass ampoules and development of evaluation methods for its application.
【24h】

A strategy for reducing particulate contamination on opening glass ampoules and development of evaluation methods for its application.

机译:减少开口玻璃安瓿瓶上颗粒污染的策略及其应用评估方法的发展。

获取原文
获取原文并翻译 | 示例
           

摘要

A single-dose glass ampoule was developed for ease of administration. When glass ampoules are opened, resulting in contamination by particulate matter. Reducing its contamination may minimize the risk in patients due to particulates. This study reports on an attempt to reduce insoluble particulate contamination by developing methods for the precise measurement of this. A vacuum machine (VM) was used to reduce the level of insoluble particulate contamination, and a microscopy, scanning electron microscopy-energy dispersive X-ray spectrometer (SEM-EDS) and inductively coupled plasma-atomic emission spectrometer (ICP-AES) were used to evaluate the level of reduction. The method permitted the insoluble particle content to be reduced by up to 87.8 and 89.3% after opening 1 and 2 mL-ampoules, respectively. The morphology of the glass particulate contaminants was very sharp and rough, a condition that can be harmful to human health. The total weight of glass particles in the opened ampoules was determined to be 104 +/- 72.9 mug and 30.5 +/- 1.00 mug after opening 1 and 2 mL-ampoules when the VM was operated at highest power. The total weights were reduced to 53.6 and 50.6%, respectively for 1 and 2 mL-ampoules, compared to opening by hand. The loss of ampoule contents on opening by the VM was 6.50 and 4.67% for 1 and 2 mL-ampoules, respectively. As a result, the VM efficiently reduced glass particulate contamination and the evaluation methods used were appropriate for quantifying these levels of contamination.
机译:开发了单剂量玻璃安瓿瓶,易于管理。打开玻璃安瓿瓶时,会导致颗粒物污染。减少其污染可以最大程度地降低由于微粒引起的患者风险。这项研究报告了通过开发精确测量方法来减少不溶性颗粒污染的尝试。使用真空机(VM)减少不溶性颗粒物污染的程度,分别使用显微镜,扫描电子显微镜-能量色散X射线光谱仪(SEM-EDS)和电感耦合等离子体原子发射光谱仪(ICP-AES)用于评估减排水平。该方法允许在打开1和2 mL安瓿瓶后分别将不溶性颗粒含量减少多达87.8%和89.3%。玻璃微粒污染物的形态非常尖锐和粗糙,这种状况可能对人体健康有害。当VM以最高功率运行时,打开1和2 mL安瓿瓶后,打开的安瓿瓶中玻璃颗粒的总重量确定为104 +/- 72.9马克杯和30.5 +/- 1.00马克杯。与手动打开相比,1和2 mL安瓿瓶的总重量分别减少到53.6和50.6%。 1和2 mL安瓿瓶在VM打开时损失的安瓿含量分别为6.50和4.67%。结果,VM有效地减少了玻璃微粒污染,并且所使用的评估方法适用于量化这些污染水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号