This study aimed to evaluate the performance of the Unyvero P50 pneumonia assay, the first 'sample-in, answer-out' system for rapid identification of pathogens and antibiotic resistance markers directly from clinical specimens. Overall, Unyvero P50 displayed very good sensitivity (>95%); however, specificity was low (33%) mainly because 40% of the specimens were reported as normal flora. Specifically, one or more pathogens were identified in 28 of them. From a detailed analysis of 42 specimens selected at random, 76% of the additionally reported pathogens were confirmed present in primary specimens. Detection of selected resistance markers was compared to routine phenotypic susceptibility testing, supplemented with Checkpoints microarray system, PCR and sequencing. Concordance was mixed, primarily due to issues with panel's choice of markers and detection of some intrinsic beta-lactamases. Finally, we offer a critical analysis of the assay's microbial panel and resistance markers and provide suggestions for improvement. (C) 2016 Elsevier Inc. All rights reserved.
机译:这项研究旨在评估Unyvero P50肺炎检测的性能,这是第一个直接从临床标本中快速鉴定病原体和抗生素抗性标记物的“进样,应答”系统。总体而言,Unyvero P50显示出非常好的灵敏度(> 95%);然而,特异性较低(33%),主要是因为据报道有40%的标本为正常菌群。具体而言,在其中的28种中鉴定出一种或多种病原体。通过对随机选择的42个标本的详细分析,可以确定在原始标本中还存在76%的额外报告的病原体。将选择的抗性标记物的检测与常规表型敏感性测试进行了比较,并补充了Checkpoints微阵列系统,PCR和测序。一致性参差不齐,主要是由于专家组选择标记和检测某些内在β-内酰胺酶的问题。最后,我们对测定的微生物组和耐药标记物进行了严格的分析,并提出了改进建议。 (C)2016 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号