首页> 外文期刊>Canadian acoustics >Management of amplified sound generated by band-shell performances in a dynamic urban setting
【24h】

Management of amplified sound generated by band-shell performances in a dynamic urban setting

机译:在动态的城市环境中管理乐队演奏所产生的放大声音

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Alberta Infrastructure is involved in a project to develop a system and procedure for monitoring and controlling the amplified performances. The intent was to provide Sound System Operators with a clear indicator of their sound levels so they could voluntarily take action to limit it. A warning light is triggered to indicate that the levels are approaching the limit and a horn is triggered to indicate that the limit has been exceeded. The locations of the measurement stations were chosen to be unobtrusive and intercept the line of site from the stage to the affected condominiums/apartments, northeast and northwest of the stage. Investigations detected existing background noise levels in the northeast community ranging from 47 dB(A) to 56 dB(A). The implementation of sound source localization logic into the software program resulted in a 98% reduction in false triggers at measuring station #2.
机译:艾伯塔省基础设施参与了一个项目,该项目旨在开发用于监视和控制放大性能的系统和程序。目的是为声音系统操作员提供清晰的声音水平指示,以便他们可以自愿采取行动来限制声音水平。触发警告灯以指示液位已接近极限,并触发喇叭以指示已超过极限。测量站的位置应选择为不引人注目,并与从舞台到舞台的东北和西北的受影响公寓/公寓的位置线相交。调查发现东北社区现有的背景噪声水平为47 dB(A)至56 dB(A)。在软件程序中实施声源定位逻辑后,测量站2的错误触发减少了98%。