A method capable of determining 3 PAHs: benzo[a]pyrene, benzo[b]fluoranthene and benzo[k]fluoranthene in a mixture of 16 PAHs by constant wavelength mode synchronous spectrofluorimetry was developed. The limits of detection (LD) and quantification (LQ) are between 0.09 and 0.23 mug/l for benzo[a]pyrene, 0.19 and 0.46 mug/l for benzo[b]fluoranthene and 0.3 and 0.44 mug/l for benzol[k]fluoranthene.
机译:开发了一种能够通过恒定波长模式同步荧光光谱法测定16种PAHs混合物中的3种PAHs的方法:苯并[a] re,苯并[b]荧蒽和苯并[k]荧蒽。苯并[a] py的检出限(LD)和定量限(LQ)在0.09和0.23杯/升之间,苯并[b]荧蒽的检出限在0.19和0.46杯/升之间,苯并[k]在0.3和0.44杯/升之间]荧蒽。