Biological treatment of high-strength nitrogen wastewater by a combined anaerobic (upflow sludge bed filter,UBF)/aerobic (membrane bioreactor,MBR) system has been studied.This system exhibited high performance on the removal of organic matter and nitrogen simultaneously.Organic and nitrogen concentrations increased from 6,000 to 14,500 mg/L and 300 to 1,000 mg/L,respectively.At the internal recycle ratio of Q (Q is the influent flow rate),average removal efficiencies of organic and total nitrogen were found to be 99 and 46%,respectively with the relatively short HRT of 24 h.When operated with the insufficient alkalinity supply,the organic removal efficiency in anaerobic reactor reduced from 98 to 82%.At high influent ammonia concentration,ammonification which is the dissimilatory nitrate reduction to NH_4~+was observed.In case of membrane fouling,transmembrane pressure (TMP) of the combined process was about 9 times higher than that of a unit MBR under same operation conditions.The reason of severe fouling in the combined system might be caused by increased extracellular polymeric substance (EPS) and hydrophobicity.EPS composition and SUVA were more sensitive parameters than surface charge and total EPS content,with respect to the change of internal recycle ratio 100-300%.
机译:研究了厌氧(上流污泥床滤池,UBF)/好氧(膜生物反应器,MBR)组合系统对高强度氮废水的生物处理,该系统在去除有机物和氮的同时具有高性能。氮浓度分别从6,000 mg / L增加到14,500 mg / L和300 mg / L增加到1,000 mg / L。在Q的内部循环比(Q为进水流速)下,有机和总氮的平均去除效率为99和HRT相对较短的24 h分别为46%。当碱度供应不足时,厌氧反应器中的有机去除效率从98%降至82%。在高进水氨浓度下,氨化是将硝酸盐还原为NH_4在膜污染的情况下,在相同的操作条件下,组合过程的跨膜压力(TMP)约为单元MBR的9倍。相对于内部循环比100-300的变化,组合系统中的严重污垢可能是由细胞外聚合物(EPS)和疏水性增加引起的。EPS组成和SUVA是比表面电荷和EPS总含量更敏感的参数%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号