The aim of this work was to determine the content of cadmium(II) and lead(II) in drinking spring and well waters from rural part of south Serbia,as in a tap water.We have examined the Jablanica river water as well,which is passing by close to the wells.The analysis of metal ions were carried out simultaneously in examined samples of water using a computerized potentiometric stripping analyzer (PSA) of domestic design and manufacture (Faculty of Technology,Novi Sad and "Electrouniverzal",Leskovac).PSA,an electroanalytical technique with high sensitivity and selectivity,applied using mercury thin film electrode,as a working electrode,by standard addition method in the presence of two supporting electrolytes to adjust pH values of examined samples.In the first case,the pH values of examined samples were adjusted at 2 by hydrochloric acid and in the second,the pH values were adjusted at 5.6 by acetate buffer contained 1.0 M NH4Ac/0.5 M HC1 in addition of 1.0 mol/dm3 chloride ions in form of NH4Cl.The deposition potentials from -1.0 to -1.3 V were examined,in order to define the optimal electrolysis potential,and pre-electrolysis time of 15 min were used.The procedure was applied to water samples and the results were compared with Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) as reference method.
机译:这项工作的目的是测定自塞尔维亚南部农村地区饮用的泉水和井水中自来水中镉和铅的含量。我们还研究了贾布兰尼察河水,正在使用国产设计和制造的计算机电位电位溶出分析仪(PSA)同时对所检查的水样中的金属离子进行分析(Novi Sad技术学院和“ Electrouniverzal”,莱斯科瓦茨) PSA是一种高灵敏度和高选择性的电分析技术,它采用汞薄膜电极作为工作电极,通过标准添加方法在两种支持电解质的存在下调节被测样品的pH值。用盐酸将被测样品的pH值调节为2,第二次,用醋酸缓冲液将pH值调节为5.6,该缓冲液中含有1.0 M NH4Ac / 0.5 M HCl和1.0 mol / dm3氯离子,形式为f NH4Cl。检查沉积电位从-1.0到-1.3 V,以确定最佳的电解电位,并使用15分钟的预电解时间。该程序应用于水样品,并将结果与​​Graphite进行比较炉原子吸收光谱法(GF-AAS)作为参考方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号