首页> 外文期刊>Desalination: The International Journal on the Science and Technology of Desalting and Water Purification >Microporous polypropylene and polyethylene hollow fiber membranes: Part 3. Experimental studies on membrane distillation for desalination
【24h】

Microporous polypropylene and polyethylene hollow fiber membranes: Part 3. Experimental studies on membrane distillation for desalination

机译:微孔聚丙烯和聚乙烯中空纤维膜:第3部分。膜蒸馏脱盐的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

Three polypropylene (PP) and one polyethylene (PE) microporous hollow-fiber membranes were used in direct contact membrane distillation (DCMD) and vacuum membrane distillation (VMD) for the desalination of simulated seawater. The influence of feed temperature and feed flow on distillate pure water flux was investigated. The comparison of the PP and PE membranes in DCMD and VMD was carried out. It was found that the water flux increased with the feed temperature and feed flow in both DCMD and VMD. The data also showed that, compared with the PP membranes, higher water flux could be obtained by using PE membranes in both the DCMD and VMD processes.
机译:在直接接触膜蒸馏(DCMD)和真空膜蒸馏(VMD)中,将三层聚丙烯(PP)和一层聚乙烯(PE)微孔中空纤维膜用于模拟海水的脱盐。研究了进料温度和进料流量对馏分纯水通量的影响。进行了DCMD和VMD中PP和PE膜的比较。发现在DCMD和VMD中水通量都随着进料温度和进料流量的增加而增加。数据还表明,与PP膜相比,在DCMD和VMD工艺中使用PE膜均可获得更高的水通量。