Optimal plant operation of brackish water reverse osmosis (BWRO) desalination is studied in this work to reduce specific energy consumption (SEC). A comprehensive first-principles based mathematical model, which explicitly accounts for membrane area and hydraulic permeability, pump characteristic curves, and pressure drops along the RO train, is developed and validated by plant data. A constrained nonlinear optimization is formulated and solved for two RO trains with different service times. It is shown that a 16% reduction in SEC is possible by optimizing operating conditions within the normal operating range of the pump while maintaining the same permeate rate. Results are discussed using dimensionless parameters derived in the author's previous work. Suggestions are made to further reduce SEC in BWRO plant operation.
机译:在这项工作中,研究了微咸水反渗透(BWRO)脱盐的最佳工厂运行,以降低单位能耗(SEC)。通过工厂数据开发并验证了一个基于第一原理的综合数学模型,该模型明确考虑了膜面积和水力渗透率,泵的特性曲线以及沿反渗透系的压降。针对两个具有不同服务时间的反渗透列车,制定并解决了约束非线性优化问题。结果表明,通过在泵的正常运行范围内优化运行条件,同时保持相同的渗透率,可以将SEC降低16%。使用作者先前工作中得出的无量纲参数讨论了结果。建议进一步减少BWRO工厂运行中的SEC。