Evaluation of the accuracy of linear measurements on spiral computed tomography-derived three-dimensional images and its comparison with digital cephalometric radiography

机译:螺旋CT三维图像对线性测量准确性的评估及其与数字头颅射线照相术的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: The aim of the study was to evaluate the accuracy of linear measurements obtained from reconstructed spiral CT images of human dry skulls in three planes by comparing them with direct skull measurements, and then to compare these with measurements made on photostimulable phosphor cephalograms. Methods: Using a Siemens Somatom Sensation spiral CT scanner (Munich, Germany), CT images of six human dry skulls were imported into imaging software (Mimics 11.02 Materialise, Leuven, Belgium) and the measurements made were compared to the direct measurements made using a digital calliper (500-171, CD-6C, Mitutoyo, Kawasaki, Japan). The measurements were also compared to those made on frontal and lateral cephalograms taken using a digital cephalostat (Planmeca Oy, Helsinki, Finland). The mean of the 15 linear measurements obtained were compared using the paired Student's t-test. Results: CT measurements did not show a significant difference from the direct skull measurements (P < 0.05) in all three planes except for two midsagittal measurements in the anteroposterior plane. Cephalometric measurements were comparable to direct skull measurements for midsagittal measurements in the anteroposterior plane, but showed a significant difference when bilateral measurements were considered. Cephalometric measurements also showed a significant difference in the transverse plane from direct measurements and CT measurements; however, they did not display a significant difference between direct skullmeasurements andCTmeasurements for most parameters in the vertical plane. Conclusion: Linear measurements on the spiral CT were comparable to anatomical measurements and were more reliable than cephalometric measurements. Cephalometric measurements were acceptable for midsagittal measurements in the anteroposterior plane, but showed a significant variation from anatomical and CT measurements in most other parameters.
机译:目的:本研究的目的是通过将人类干颅骨的螺旋CT重建图像在三个平面中进行比较,以将其与直接颅骨测量结果进行比较,然后将其与在光刺激性荧光脑波图上进行的测量结果进行比较,以评估线性测量结果的准确性。方法:使用西门子Somatom Sensation螺旋CT扫描仪(德国慕尼黑),将六个人类干颅骨的CT图像导入成像软件(Mimics 11.02 Materialise,比利时鲁汶),并将测量结果与使用数字游标卡尺(500-171,CD-6C,日本川崎三丰)。还将测量结果与使用数字式头颅调节器(Planmeca Oy,赫尔辛基,芬兰)拍摄的额头和侧面头颅图进行的测量结果进行比较。使用配对的学生t检验比较获得的15个线性测量的平均值。结果:除了在前后平面中进行两次矢状中位测量外,在所有三个平面中CT测量均未显示与直接颅骨测量有显着差异(P <0.05)。头颅测量与前后颅骨矢状位测量的直接颅骨测量结果相当,但考虑到双侧测量结果,则显示出显着差异。头颅测量法也显示出与直接测量法和CT测量法相比,横断面的显着差异;但是,对于垂直平面中的大多数参数,直接头骨测量和CT测量之间没有显着差异。结论:螺旋CT上的线性测量与解剖学测量相当,并且比头颅测量更可靠。头颅测量可用于前后平面中矢状位测量,但在大多数其他参数上与解剖学和CT测量相比有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号