...
首页> 外文期刊>Vox Sanguinis: International Journal of Blood Transfusion and Immunohaematology >Influence of multicomponent apheresis on donors' haematological and coagulation parameters, iron storage and platelet function
【24h】

Influence of multicomponent apheresis on donors' haematological and coagulation parameters, iron storage and platelet function

机译:多成分血液分离对供血者血液学和凝血参数,铁存储和血小板功能的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Background and Objectives Multicomponent collection (MCC) enables production and processing of various blood components during one apheresis session. In this prospective crossover study, the effects of donating platelets (PLTs) and packed red blood cells (PRBCs) on donor's blood cell count, coagulation, PLT function and iron state were analysed. Materials and Methods Forty-eight MCCs were performed using two different cell separators (Fenwal Amicus?, CaridianBCT Trima Accel?). Two units of platelet concentrates and one unit of PRBCs were collected during each session. Full blood cell count and iron status were obtained on day 0 before and after apheresis, day 2, day 14 and day 42. PLT function was analysed by aggregometry and rotation thromboelastometry in parallel with coagulation tests before and after MCC and at day 2. Results Multicomponent collection was well tolerated without adverse side effects. Blood cell count and iron parameters declined and most of them (haemoglobin, haematocrit, transferrin, transferrin saturation and ferritin) were significantly below baseline values until at least day 42 after donation. Absent iron stores were seen in 31·3% of the donors. In contrast, PLTs significantly exceeded pre-donation values after 14days and remained significantly increased for 42days. After 2days, coagulation parameters were only slightly (P>0·05) altered, whereas PLT function was significantly reduced. Conclusion Multicomponent collection is an obviously safe procedure; however, the significant long-term impact on the donor's blood count and iron store, as well as impaired PLT function, has to be considered in regard to donor safety.
机译:背景与目的多成分采集(MCC)可以在一次血液采血过程中生产和处理各种血液成分。在这项前瞻性交叉研究中,分析了捐赠血小板(PLT)和堆积的红细胞(PRBC)对捐赠者血细胞计数,凝血,PLT功能和铁状态的影响。材料和方法使用两种不同的细胞分离器(Fenwal Amicus?,CaridianBCT Trima Accel?)进行48个MCC。在每个疗程中收集了两份血小板浓缩液和一份PRBC。在血液分离前后的第0天,第2天,第14天和第42天获得全血细胞计数和铁状态。同时,通过凝集测定法和旋转血栓弹性测定法与MCC前后,第2天的凝血试验同时分析PLT功能。结果多组分收集具有良好的耐受性,且无不良副作用。血细胞计数和铁参数下降,并且其中大多数(血红蛋白,血细胞比容,转铁蛋白,转铁蛋白饱和度和铁蛋白)均显着低于基线值,直到捐赠后至少第42天。在捐赠者中有31·3%的人没有铁存储。相反,PLT在14天后显着超过捐赠前的值,并在42天后仍显着增加。 2天后,凝血参数仅轻微改变(P> 0·05),而PLT功能明显降低。结论多组分收集是一种明显安全的方法。然而,就捐赠者的安全性而言,必须考虑对捐赠者的血球计数和铁存储的重大长期影响以及PLT功能受损。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号