首页> 外文期刊>Magnetic resonance imaging: An International journal of basic research and clinical applications >Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging
【24h】

Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging

机译:在膝盖MR成像中使用BLADE序列消除运动和搏动伪影

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (COR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE COR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images.
机译:这项研究的目的是评估在膝部磁共振成像检查中质子密度(PD)-BLADE序列减少或什至消除运动和脉动血流伪影的能力。连续进行了80例常规扫描以检查膝盖的患者参加了这项研究。比较了有无BLADE的以下几对序列:(a)35例患者的PD涡轮自旋回波(TSE)矢状(SAG)脂肪饱和(FS),(b)19例患者的PD TSE冠状(COR)FS,( c)13例T2 TSE轴向患者,(d)13例PD TSE SAG。定性和定量分析均基于正常解剖结构的信噪比(SNR),对比噪声比(CNR)和相对对比(ReCon)测量进行。定性分析由经验丰富的放射科医生进行。此外,评估了图像运动和脉动伪像的存在。根据不同序列和解剖结构的SNR,CRN和ReCon的结果,BLADE序列在19例中有明显优势,而相应的常规序列仅在6例中有显着优势。在所有情况下,BLADE序列都消除了运动伪影。但是,在(a)六个PD TSE SAG FS,(b)三个PD TSE COR FS,(c)三个PD TSE SAG和(d)两个T2 TSE轴向常规序列中显示了运动伪影。在我们的结果中,发现在PD FS序列(矢状和冠状)中,BLADE和常规序列之间在消除运动和脉动血流伪影方面的差异具有统计学意义。在所有比较中,PD FS BLADE序列(冠状和矢状)在图像质量分类方面均明显优于相应的常规序列。总之,该技术似乎能够潜在地消除MR图像中的运动和脉动流伪像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号