首页> 外文期刊>Magnetic resonance imaging: An International journal of basic research and clinical applications >Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3 T
【24h】

Multichannel transceiver dual-tuned RF coil for proton/sodium MR imaging of knee cartilage at 3 T

机译:多通道收发器双调谐RF线圈,用于在3 T时对膝软骨进行质子/钠MR成像

获取原文
获取原文并翻译 | 示例

摘要

Sodium magnetic resonance (MR) imaging is a promising technique for detecting changes of proteoglycan (PG) content in cartilage associated with knee osteoarthritis. Despite its potential clinical benefit, sodium MR imaging in vivo is challenging because of intrinsically low sodium concentration and low MR signal sensitivity. Some of the challenges in sodium MR imaging may be eliminated by the use of a high-sensitivity radiofrequency (RF) coil, specifically, a dual-tuned (DT) proton/sodium RF coil which facilitates the co-registration of sodium and proton MR images and the evaluation of both physiochemical and structural properties of knee cartilage. Nevertheless, implementation of a DT proton/sodium RF coil is technically difficult because of the coupling effect between the coil elements (particularly at high field) and the required compact design with improved coil sensitivity. In this study, we applied a multitransceiver RF coil design to develop a DT proton/sodium coil for knee cartilage imaging at 3 T. With the new design, the size of the coil was minimized, and a high signal-to-noise ratio (SNR) was achieved. DT coil exhibited high levels of reflection S11 (~-21 dB) and transmission coefficient S12 (~-19 dB) for both the proton and sodium coils. High SNR (range 27-38) and contrast-to-noise ratio (CNR) (range 15-21) were achieved in sodium MR imaging of knee cartilage in vivo at 3-mm ~3 isotropic resolution. This DT coil performance was comparable to that measured using a sodium-only birdcage coil (SNR of 28 and CNR of 20). Clinical evaluation of the DT coil on four normal subjects demonstrated a consistent acquisition of high-resolution proton images and measurement of relative sodium concentrations of knee cartilages without repositioning of the subjects during the same MR scanning session.
机译:钠磁共振(MR)成像是一种有前途的技术,可用于检测与膝骨关节炎相关的软骨中蛋白聚糖(PG)含量的变化。尽管具有潜在的临床益处,但由于钠浓度低和MR信号敏感性低,体内钠MR成像仍具有挑战性。钠MR成像中的一些挑战可以通过使用高灵敏度射频(RF)线圈来解决,特别是使用双调谐(DT)质子/钠RF线圈,它可以促进钠和质子MR的共配准图像以及膝盖软骨理化和结构特性的评估。然而,由于线圈元件之间的耦合效应(特别是在高磁场下)和所需的紧凑设计以及提高的线圈灵敏度,在技术上难以实现DT质子/钠RF线圈。在这项研究中,我们应用了多收发器射频线圈设计来开发用于3 T膝关节软骨成像的DT质子/钠线圈。通过新设计,线圈的尺寸得以最小化,并且信噪比高( SNR)。 DT线圈对于质子线圈和钠线圈都表现出高水平的反射S11(〜-21 dB)和透射系数S12(〜-19 dB)。在3mm〜3各向同性的分辨率下,在体内膝关节软骨的钠MR成像中实现了高SNR(范围27-38)和对比噪声比(CNR)(范围15-21)。这种DT线圈性能与仅使用钠鸟笼线圈所测得​​的性能相当(SNR为28,CNR为20)。在四个正常受试者上进行DT线圈的临床评估表明,在相同的MR扫描过程中,无需重新放置受试者,就可以获得一致的高分辨率质子图像采集和膝软骨相对钠浓度的测量值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号