首页> 外文期刊>Magnetic resonance imaging: An International journal of basic research and clinical applications >Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: Case report
【24h】

Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss: Case report

机译:冠状动脉支架由于信号丢失而在心脏磁共振成像上模仿心内血栓:病例报告

获取原文
获取原文并翻译 | 示例
           

摘要

Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year.This case report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology.While the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor.
机译:自从引入针对冠状动脉疾病的经皮冠状动脉介入治疗以来,数千例患者已经接受了冠状动脉支架植入治疗。此外,每年都有几例冠状动脉支架患者接受心脏磁共振(CMR)成像检查。该病例报告是一名77岁的男性患者,之前曾接受过在左旋支动脉植入冠状动脉支架的治疗。他接受了CMR成像,显示左心房14×21 mm的突起。心脏对比计算机断层扫描未显示任何心脏病理。虽然已知与金属植入设备相关的MRI信号丢失,但我们报道了一种情况,其中左旋支动脉植入冠状动脉支架导致模拟心内血栓/肿瘤的心内信号丢失。 。