The objectives of this study were to optimize T2-weighted hybrid-RARE pulse sequences for clinical MR imaging of the liver, and to compare them to the conventional spin-echo (CSE) sequence. Specifically, the ranges of the echo train length (ETL) and the effective echo time (TEeff) were investigated to optimize image quality and liver-spleen contrast, in healthy volunteers, A total of thirteen volunteers were scanned at 1.5 Tesla with an extensive array of hybrid-RARE scans, The images were analyzed quantitatively with respect to CNR (contrast-to-noise ratio of spleen vs, liver), SNR (signal to noise ratio of the spleen), SIR (signal intensity ratio of liver and spleen) and CDR (contrast difference ratio between the spleen and liver), The images were also analyzed qualitatively with respect to image sharpness, vascular artifacts, ghosting, chemical shift, and truncations, Results of quantitative analysis indicated that CDR and SIR of hybrid-RARE at higher ETL (> 13) were consistently better than both the reference CSE and the lower ETL sequences (p < 0.05) at all TEeff. SNR was slightly inferior for all hybrid-RARE sequences than for the CSE sequence, Image quality for hybrid-RARE sequences with ETL > 13 proved to be consistently better than that for the CSE (TE = 90 ms) with respect to imaging sharpness, vascular artifacts and ghosting artifacts (p < 0.05), In conclusion, the optimized hybrid-RARE sequences with ETL greater than or equal to 13 are capable of producing sharp and relatively artifact free images with the advantage of a much greater acquisition time efficiency. (C) 1997 Elsevier Science Inc.
机译:这项研究的目的是优化肝脏临床MR成像的T2加权杂交RARE脉冲序列,并将其与常规自旋回波(CSE)序列进行比较。具体来说,研究了回声训练长度(ETL)和有效回声时间(TEeff)的范围,以优化图像质量和肝脾对比度,在健康志愿者中,总共有13名志愿者在1.5特斯拉下进行了广泛的扫描混合RARE扫描的图像,针对CNR(脾脏与肝脏的对比噪声比),SNR(脾脏的信噪比),SIR(肝脏和脾脏的信号强度比)进行了定量分析还对图像的清晰度,血管伪影,重影,化学位移和截短进行了定性分析。定量分析结果表明,杂交RARE的CDR和SIR为在所有TEeff上,较高的ETL(> 13)始终优于参考CSE和较低的ETL序列(p <0.05)。对于所有杂交RARE序列,其SNR均比CSE序列稍差。在成像清晰度,血管方面,ETL> 13的杂交RARE序列的图像质量被证明始终优于CSE(TE = 90 ms)总而言之,具有大于或等于13的ETL的优化混合RARE序列能够产生清晰且相对无伪影的图像,并具有更高的采集时间效率。 (C)1997爱思唯尔科学公司

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号