首页> 外文期刊>Magma: Magnetic resonance materials in physics, biology, and medicine >Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography
【24h】

Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography

机译:使用高时间分辨率相衬和简单平均的纵向心肌峰速度可与组织多普勒超声心动图相比

获取原文
获取原文并翻译 | 示例
           

摘要

Object Phase contrast imaging is widely used to measure blood velocity. However tissue Doppler imaging (TDI) echocardiography is the reference for myocardial velocity assessment. This study aims at validating the ability of phase contrast (PC) sequences to correctly assess myocardial velocities and to compare these velocities to TDI. The phase contrast sequence was performed with breathhold parameters and with parameters tuned to increase temporal resolution in free breathing. Materials and methods Left and Right auriculo-ventricular annuluses longitudinal velocities were recorded on six healthy volunteers with different temporal resolutions (TDI: 5 ms, breath-hold PC: 94 ms and free-breathing PC: 19 ms). Free-breathing PC was obtained by averaging of three excitations. Amplitudes of four standard echocardiographic and clinically relevant myocardial longitudinal velocity waves were compared: Early filling and auricular, systolic and isovolumic contractions. Results Isovolumic contraction waves were only visible with free-breathing PC and TDI. The differences with the reference TDI wave velocities were lower (p = 0.02) for free-breathing PC (19.2 ± 2.6 %) than for breath-hold PC (28.1 ± 2.9 %). These differences for free-breathing PC were close to (p = 0.21) the coefficient of variation of the measurements provided by TDI (14.8 ± 1.2 %). Conclusion Myocardial longitudinal peak velocities can be assessed with a PC sequence tuned to optimize temporal resolution.
机译:物相对比成像被广泛用于测量血流速度。然而,组织多普勒成像(TDI)超声心动图是心肌速度评估的参考。这项研究旨在验证相衬(PC)序列正确评估心肌速度并将这些速度与TDI进行比较的能力。相差序列是通过屏气参数和调整参数以提高自由呼吸的时间分辨率来执行的。材料和方法在六位健康的志愿者身上记录了左右耳室环的纵向速度,这些志愿者具有不同的时间分辨率(TDI:5 ms,屏气PC:94 ms,自由呼吸PC:19 ms)。通过平均三个激发来获得自由呼吸的PC。比较了四个标准超声心动图和临床相关的心肌纵向速度波的振幅:早期充盈和耳廓,收缩期和等容性收缩。结果等容收缩波仅在自由呼吸的PC和TDI下可见。自由呼吸型PC(19.2±2.6%)与屏气型PC(28.1±2.9%)与参考TDI波速的差异较小(p = 0.02)。自由呼吸型PC的这些差异接近(p = 0.21)TDI提供的测量值的变化系数(14.8±1.2%)。结论可以通过调整PC序列以优化时间分辨率来评估心肌的纵向峰值速度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号