Object To determine whether superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging could demonstrate signal recovery delay in irradiated areas of rat livers. We also investigated the relationship between MR imaging and histological findings. Materials and methods Twelve rats received 20 lmol iron/kg of SPIO followed by X-irradiation to the right upper abdomen 4 h later. Radiation doses were 0, 50 and 70 Gy. Hepatic signals were assessed on unenhanced T_2 * -weighted images for up to 7 days using a 9.4-Tesla scanner. The livers were excised on day 7 and examined histologically.
机译:目的确定超顺磁性氧化铁(SPIO)增强的磁共振(MR)成像是否可以证明大鼠肝脏受照区域的信号恢复延迟。我们还调查了磁共振成像和组织学发现之间的关系。材料和方法十二只大鼠接受20 lmol铁/ kg SPIO,然后在4小时后X射线照射到右上腹部。放射剂量为0、50和70 Gy。使用9.4-Tesla扫描仪在未增强的T_2 *加权图像上评估肝信号长达7天。在第7天切除肝脏并进行组织学检查。