首页> 外文期刊>Magma: Magnetic resonance materials in physics, biology, and medicine >Assessment of neovascular permeability in a pancreatic tumor model using dynamic contrast-enhanced (DCE) MRI with contrast agents of different molecular weights
【24h】

Assessment of neovascular permeability in a pancreatic tumor model using dynamic contrast-enhanced (DCE) MRI with contrast agents of different molecular weights

机译:使用动态对比增强(DCE)MRI和不同分子量的对比剂评估胰腺肿瘤模型中的新生血管通透性

获取原文
获取原文并翻译 | 示例
           

摘要

We evaluated the relationship of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)-derived pharmacokinetic parameters and contrast agents with different molecular weights (MW) in a pancreatic tumor mouse model. Materials and methods: Panc02 tumors were induced in mice at the hind leg. DCE-MRI was performed using Gadolinium (Gd)-based contrast agents with different MW: Gd-DOTA (0.5 kDa), P846 (3.5 kDa), and P792 (6.47 kDa). Quantitative vascular parameters (AUC, K ~(trans), V _e, and V _p) were calculated according to a modified Tofts two-compartment model. Values for all contrast groups were compared for tumor and control (muscle) tissues. Results: Values for K ~(trans) and V _e were significantly higher in tumor tissue than in muscle tissue. When comparing contrast agents, lowest absolute K trans values were observed using P792. The relative increase in K ~(trans) in tumor tissue compared with normal tissue was highest after the use of P792. In both tumor and normal tissues, K trans decreased with increasing molecular weight of the contrast agent used. Conclusion: It was demonstrated that values for the different DCE-MRI vascular (permeability) parameters are highly dependent on the contrast agent used. Due to their potential to better differentiate tumor from muscle tissue, higher molecular weight contrast agents show promise when evaluating tumors using DCE-MRI.
机译:我们在胰腺肿瘤小鼠模型中评估了动态对比增强磁共振成像(DCE-MRI)衍生的药代动力学参数与不同分子量(MW)的对比剂之间的关系。材料和方法:Panc02肿瘤是在小鼠后腿处诱发的。使用具有不同MW的基于contrast(Gd)的造影剂进行DCE-MRI:Gd-DOTA(0.5 kDa),P846(3.5 kDa)和P792(6.47 kDa)。根据改良的Tofts两室模型计算血管定量参数(AUC,K〜(trans),V_e和V_p)。比较所有对比组的肿瘤和对照(肌肉)组织的值。结果:肿瘤组织中的K〜(trans)和V _e值显着高于肌肉组织。比较造影剂时,使用P792观察到最低的绝对K反式值。使用P792后,肿瘤组织中K〜(trans)相对于正常组织的相对增加最高。在肿瘤和正常组织中,K trans随所用造影剂分子量的增加而降低。结论:已证明,不同DCE-MRI血管(通透性)参数的值高度依赖于所使用的造影剂。由于它们具有更好地将肿瘤与肌肉组织区分开的潜力,因此在使用DCE-MRI评估肿瘤时,较高分子量的造影剂显示出希望。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号