Repeatability of SphygmoCor pulse wave analysis in assessing arterial wave reflection in pregnancy using applanation tonometry

机译:SphygmoCor脉搏波分析在压平眼压计评估孕妇动脉波反射中的可重复性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Objective: To estimate clinical agreement in relation to measuring aortic augmentation index (AIX-75) in pregnancy in a routine clinical setting. Methods: A hospital-based clinical agreement study of 20 women in which two trained nurses alternated in measuring arterial function (AIX standardized to a heart rate of 75 beats-per-minute, AIX-75) on a single occasion in triplicate, after participants had rested semi-recumbent for 15 min. Right brachial blood pressure (BP) was measured using the Microlife 3BTO-A oscillometric device. Radial applanation pulse wave analysis (PWA) was undertaken according to current guidelines using the SphygmoCor device with a hand-held Millar tonometer applanated at the right radial artery. Each nurse was blinded to others PWA results. Observer agreement was assessed using the Bland-Altman "limits of agreement" (LOA, mean difference +/- 2 SD) approach. Results: Median gestation was 37 weeks (range: 12-42), mean age 31 years, 30% nulliparous, mean brachial BP 128/79mm Hg. Based on all six PWA measurements, mean AIX-75 was 11.7 (range: -18 to +35). The between-observer LOA was 0.1 +/- 11.0 and the within-observer LOA's were 1 +/- 10 and -2+8 for the two nurses. Observer differences did not vary systematically with the magnitude of AIX-75. Conclusion: AIX-75 can be measured by nurses using PWA in pregnancy with a high level of observer agreement.
机译:目的:在常规临床环境中,评估与测量妊娠期主动脉扩张指数(AIX-75)相关的临床协议。方法:一项基于医院的临床协议研究,研究对象为20名女性,其中两名受过训练的护士在参与者参加后,一次三次重复测量动脉功能(将AIX标准化为心律每分钟75次心跳,AIX-75)。半卧位休息了15分钟。使用Microlife 3BTO-A示波仪测量右臂血压(BP)。根据目前的指南,使用SphygmoCor设备进行undertaken骨扁平脉搏波分析(PWA),并将手持Millar眼压计压在右侧radial动脉上。每个护士对其他PWA结果都不了解。使用Bland-Altman“协议限制”(LOA,平均差异+/- 2 SD)方法评估观察者的一致性。结果:中位妊娠为37周(范围:12-42),平均年龄31岁,未产卵30%,平均肱动脉BP 128 / 79mm Hg。根据所有六个PWA测量值,平均AIX-75为11.7(范围:-18至+35)。两位护士的观察者之间的LOA为0.1 +/- 11.0,观察者内部的LOA为1 +/- 10和-2 + 8。观察者差异不会随AIX-75的大小而系统地变化。结论:孕妇在怀孕期间使用PWA可以测量AIX-75,观察者的同意水平很高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号