首页> 外文期刊>Haemophilia: the official journal of the World Federation of Hemophilia >Inter-observer reliability of three different radiographic scores for adult haemophilia.
【24h】

Inter-observer reliability of three different radiographic scores for adult haemophilia.

机译:成人血友病的三种不同射线照相评分的观察者间可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the inter-observer reliability of radiological assessment systems for haemophilic arthropathy, three senior orthopaedic surgeons with expertise in haemophilia independently evaluated a total of 527 joint radiographs of adult haemophilia patients, without any knowledge of the clinical data. This study was the largest study to evaluate the reliability of radiological assessment systems. As for the results, the Arnold-Hilgartner staging system showed moderate reliability (kappa value: kappa = 0.44, P = 0.000), and the De Palma grading system and the Pettersson scoring system showed fair reliability (kappa = 0.40, P = 0.000) and slight reliability (kappa = 0.12, P = 0.000) respectively. As for the reliability of the eight findings in the Pettersson scoring system, three findings, which were 'narrowing of joint space' (kappa = 0.70 P = 0.000), 'irregular subchondral surface' (kappa = 0.58, P = 0.000) and 'erosion of joint margins' (kappa = 0.56, P = 0.000), showed substantial or moderate reliability. Other findings showed fair or less reliability. The traditional radiological assessment systems showed poor inter-observer reliability. Both progressive scales showed higher reliability than the additive scale, and the three findings in the Pettersson scoring system showed good reliability. These results suggested that the progressive scale, including the three reliable radiological findings, might be a more reliable radiological assessment system.
机译:为了评估血友病性关节炎放射学评估系统的观察员间可靠性,三名具有血友病专长的骨科高级医师独立评估了共527例成人血友病患者的X射线照相,而对临床数据一无所知。这项研究是评估放射学评估系统可靠性的最大研究。至于结果,Arnold-Hilgartner分期系统显示出中等可靠性(kappa值:kappa = 0.44,P = 0.000),De Palma评分系统和Pettersson评分系统显示出中等可靠性(kappa = 0.40,P = 0.000)。和轻微可靠性(kappa = 0.12,P = 0.000)。至于Pettersson评分系统中八项发现的可靠性,三项发现分别是“关节间隙变窄”(kappa = 0.70 P = 0.000),“不规则软骨下表面”(kappa = 0.58,P = 0.000)和“关节边缘的侵蚀(kappa = 0.56,P = 0.000)显示出基本或中等的可靠性。其他发现显示出中等或较低的可靠性。传统的放射学评估系统观察者之间的可靠性差。两种累进量表均显示出比加性量表更高的可靠性,Pettersson评分系统中的三个发现均显示出良好的可靠性。这些结果表明,包括三个可靠的放射学发现在内的累进量表可能是一个更可靠的放射学评估系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号