Locking, jamming, and ratchet mechanisms of sliding surgical knots topologically revisited.

机译:重新研究了滑动手术结的锁定,卡紧和棘轮机构。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: The geometry of lockable, ratchet, or jamming sliding surgical knots was assessed to enhance practical and topological understanding of knots among surgeons. METHODS: Using a database of more than 100 surgical knots, 29 knots that reportedly feature locking, ratchet, or jamming mechanisms were topologically assessed for their ability to lock antegradely or retrogradely, to lock by assuming their flat geometry, or to jam. RESULTS: Eighteen of the 29 investigated surgical knots have previously been mistakenly categorized. Topologically, the concept of a true ratchet knot is a fallacy. CONCLUSIONS: Surgical knots may be consistently classified on the basis of precise and detailed definition of various anti-backsliding geometrical characteristics of knots.
机译:背景:对可锁定,棘齿或卡死的滑动式手术结的几何形状进行了评估,以增强外科医生对结的实用和拓扑学理解。方法:使用一个包含100多个手术结的数据库,从拓扑上评估了29个据报道具有锁定,棘轮或阻塞机制的结,以判断其正向或逆向锁定,通过假定其平坦几何形状或卡住的能力。结果:29个调查过的手术结中有18个以前被错误地分类了。在拓扑上,真正的棘轮结概念是谬论。结论:可以根据各种抗结的抗滑移几何特征的精确和详细定义对手术结进行一致的分类。