Purge gas in flare systems is used to avoid burnback in the flare stack. We have used computational fluid dynamics (CFD) methods to calculate the purge gas flow rate in a flare stack with a velocity seal. We constructed a simulation model of the purging process for different purge rates. As the results show, the baffle size has a significant effect on the oxygen distribution in the flare. When the first baffle/seal diameter ratio is d/D = 0.92 and hydrocarbons are discharged in the flare, the minimum safe purge gas flow rate is 0.05 m/s. However, when the hydrogen content in the discharge gas is high, the minimum safe purge rate is higher: 0.1 m/s. But if the purge rate is maintained at the level recommended by API 521-2007 (0.012 m/s when discharging hydrocarbon gases), the ratio d/D should not be greater than 0.75. In this case, when discharging gas with high hydrogen content, the minimum safe purge rate is 0.02 m/s.
机译:火炬系统中使用吹扫气体来避免火炬烟囱中的回燃。我们已经使用计算流体动力学(CFD)方法来计算带有速度密封的火炬烟囱中的吹扫气体流速。我们构建了不同吹扫速率的吹扫过程的仿真模型。结果表明,折流板尺寸对火炬中的氧气分布有很大影响。当第一挡板/密封件的直径比为d / D = 0.92且碳氢化合物排放到火炬中时,最小安全吹扫气体流速为0.05 m / s。但是,当排气中的氢含量较高时,最小安全吹扫速率会更高:0.1 m / s。但是,如果吹扫速率保持在API 521-2007建议的水平(排放烃类气体时为0.012 m / s),则d / D之比不应大于0.75。在这种情况下,排放高氢含量的气体时,最小安全吹扫速度为0.02 m / s。