首页> 外文期刊>World Journal of Microbiology & Biotechnology >Poly(vinylferrocene)-poly(ethylene glycol) glutamate oxidase electrode for determination of L-glutamate in commercial soy sauces
【24h】

Poly(vinylferrocene)-poly(ethylene glycol) glutamate oxidase electrode for determination of L-glutamate in commercial soy sauces

机译:聚(乙烯基二茂铁)-聚(乙二醇)谷氨酸氧化酶电极测定商业酱油中的L-谷氨酸

获取原文
获取原文并翻译 | 示例
           

摘要

An amperometric L-glutamate oxidase (GLOD) electrode based on a multilayer of polymer films was developed for the high selective determination of L-glutamate. The multilayer film consisted of three layers as the following configuration i.e., inner membrane of electropolymerized 1,3-diaminobenzene, middle layer of L-GLOD entrapped in photopolymerized poly(vinylferrocene)-poly(ethylene glycol) hydrogel polymer, and outer dialysis membrane. In this manner, the sensor could eliminate interferences and was able to work at a low potential poised at +0.085 V vs. Ag/AgCl. When used in a flow injection system, the sensor responded to L-glutamate in the range 0.5-8.0 mM, with a sensitivity of 9.48 nA mM(-1). The sensor was stable for 5 days of continuous uses (250 assays) and retained 60% activity after 16 days. When used to analyse the L-glutamate contents of a number of different off-the-shelf soy sauces, the sensor gave results in good agreement with the standard colorimetric method.
机译:开发了一种基于多层聚合物薄膜的安培型L-谷氨酸氧化酶(GLOD)电极,用于高选择性测定L-谷氨酸。该多层膜由三层构成,即以下的结构,即,电聚合的1,3-二氨基苯的内膜,被光聚合的聚(乙烯基二茂铁)-聚(乙二醇)水凝胶聚合物包裹的L-GLOD的中间层和外透析膜。以这种方式,该传感器可以消除干扰,并且能够在相对于Ag / AgCl的+0.085 V的低电位下工作。当用于流动注射系统时,该传感器对L-谷氨酸的响应范围为0.5-8.0 mM,灵敏度为9.48 nA mM(-1)。该传感器在连续使用5天(250次测定)后保持稳定,并在16天后保持60%的活性。当用于分析许多不同的现成酱油中L-谷氨酸含量时,该传感器的结果与标准比色法非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号