首页> 外文期刊>Chinese physics letters >Fabrication, testing and integration technologies of polymer microlens for Pt/Si Schottky-barrier infrared charge coupled device applications
【24h】

Fabrication, testing and integration technologies of polymer microlens for Pt/Si Schottky-barrier infrared charge coupled device applications

机译:用于Pt / Si肖特基势垒红外电荷耦合器件的聚合物微透镜的制造,测试和集成技术

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A novel polymer refractive microlens array has been formed on the surface of 256(V)x290(H) PtSi Schottky-barrier infrared charge coupled device (IRCCD) image sensors to improve the photoresponsivity of the IRCCD. The fabrication process flows of polymer microlens array are described. An effective aperture ratio in excess of 92% of microlens array has been achieved. An experimental facility to evaluate the optical performance of microlens array is introduced. The measurement results show, that the microlens array, indicates, better than 4% non-uniformity of focal length and high optical performance. The application of the microlens array to improve the photosensitivity of infrared CCD is discussed.
机译:一种新颖的聚合物折射微透镜阵列已经形成在256(V)x290(H)PtSi肖特基势垒红外电荷耦合器件(IRCCD)图像传感器的表面上,以提高IRCCD的光响应性。描述了聚合物微透镜阵列的制造工艺流程。已经实现了超过微透镜阵列的92%的有效开口率。介绍了评估微透镜阵列光学性能的实验设备。测量结果表明,微透镜阵列显示出优于4%的焦距不均匀性和高光学性能。讨论了微透镜阵列在提高红外CCD光敏性中的应用。