In thermal power stations, water is considered to be as one of the most important input .Its purity results in the healthiness of most of the components of power stations. Condenser is one of the important components which finally dictate the performance of the plant. Leakage in condenser allow the ingress of cooling water( raw water) vis - a - vis salts present in it to enter into the water cycle which upset the water chemistry and unit/plant performance. In the present paper the impact of impurities in water due to condenser leakage, its prevention, the mechanism of turbine deposit formation, failure of steam turbine blades and a case study of a 210 MWe unit were discussed.
机译:在火力发电厂中,水被认为是最重要的投入之一。水的纯净度会导致火力发电厂大多数组件的健康。冷凝器是最终决定电厂性能的重要组件之一。冷凝器中的泄漏使冷却水(原水)相对于其中存在的盐进入,进入水循环,这破坏了水的化学性质和装置/设备的性能。本文讨论了冷凝器泄漏对水中杂质的影响,其预防,汽轮机沉积物形成的机理,汽轮机叶片的故障以及一个210 MWe机组的案例研究。