首页> 外文期刊>The Journal of Emergency Medicine >Subarachnoid hemorrhage diagnosis by computed tomography and lumbar puncture: Are fifth generation CT scanners better at identifying subarachnoid hemorrhage?
【24h】

Subarachnoid hemorrhage diagnosis by computed tomography and lumbar puncture: Are fifth generation CT scanners better at identifying subarachnoid hemorrhage?

机译:通过计算机断层扫描和腰椎穿刺诊断蛛网膜下腔出血:第五代CT扫描仪在识别蛛网膜下腔出血方面是否更好?

获取原文
获取原文并翻译 | 示例

摘要

This study sought to determine the sensitivity and specificity of modern computed tomography (CT) scans for the diagnosis of subarachnoid hemorrhage (SAH). No studies have been done recently with fifth generation CT scanners to look at the diagnosis of SAH. A retrospective chart review was done of Emergency Department (ED), laboratory, and hospital records at Pitt County Memorial Hospital in Greenville, North Carolina over 1 year from January 1, 2002 to December 31, 2002. Patients presented with headache and had a CT scan of the head with a fifth generation multi-detector CT scanner followed by a lumbar puncture (LP) to rule out SAH. There were 177 patients who presented to the ED with headache and went on to have a CT scan and an LP to rule out SAH. No patients who had a negative CT were found to have a subarachoid hemorrhage. It is concluded that fifth generation CT scanners are probably more sensitive than earlier scanners at detecting SAH.
机译:本研究旨在确定现代计算机断层扫描(CT)扫描对蛛网膜下腔出血(SAH)的诊断的敏感性和特异性。最近没有使用第五代CT扫描仪进行SAH诊断的研究。自2002年1月1日至2002年12月31年,在北卡罗来纳州格林维尔的皮特县纪念医院对急诊科(ED),实验室和医院记录进行了回顾性回顾,历时1年。患者出现头痛并接受了CT检查使用第五代多探测器CT扫描仪进行头部扫描,然后进行腰穿(LP)排除SAH。有177例因急诊而出现在急诊室的患者,并进行了CT扫描和LP排除SAH。没有发现CT阴性的患者发生蛛网膜下腔出血。结论是,第五代CT扫描仪在检测SAH方面可能比早期的扫描仪更加敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号