首页> 外文期刊>Water Science and Technology >Calorimetric assessment of activity in WWTP biomass
【24h】

Calorimetric assessment of activity in WWTP biomass

机译:污水处理厂生物量活动的量热评估

获取原文
获取原文并翻译 | 示例
           

摘要

A heat flux bench-scale calorimeter (Bio-RC1) has been used to assess the metabolic activity of microbial populations involved in wastewater treatment biological processes under aerobic, anoxic and anaerobic conditions. Under strictly aerobic conditions, a linear correlation was observed between oxygen uptake rate and heat flux for heterotrophic and nitrifying bacterial populations. Using the same calorimetric approach and the same apparatus, toxicity and biodegradability of a pesticides factory wastewater were investigated. The activity of heterotrophic and nitrifying aerobic communities was monitored considering both oxygen consumption and heat dissipation, whereas, under anoxic conditions, calorimetric data were compared to the traditional NUR (nitrate uptake rate) test. Heterotrophic activity was found to be 52% inhibited after toxic wastewater exposure under both aerobic and anoxic conditions and 30% inhibition was observed on autotrophic ammonia oxidation. Additionally, calorimetric measurements have been successfully applied to investigate anaerobic digestion. The thermal response of a mesophilic granular sludge to repetitive glucose pulses has been evaluated and a toxicity test has been performed by exposing the biomass to increasing concentrations of formaldehyde. [References: 19]
机译:热通量台式热量计(Bio-RC1)已用于评估在好氧,缺氧和厌氧条件下参与废水处理生物过程的微生物种群的代谢活性。在严格的有氧条件下,异养和硝化细菌种群的摄氧速率和热通量之间存在线性关系。使用相同的量热方法和相同的设备,研究了农药工厂废水的毒性和生物降解性。同时考虑了耗氧量和热耗散,监测了异养和硝化有氧群落的活动,而在缺氧条件下,量热数据与传统的NUR(硝酸盐吸收率)测试进行了比较。在有氧和缺氧条件下,有毒废水暴露后,异养活性被抑制52%,而自养氨氧化被抑制30%。另外,量热测量已成功地应用于研究厌氧消化。已经评估了嗜温颗粒污泥对重复葡萄糖脉冲的热响应,并通过将生物质暴露于不断增加的甲醛浓度中进行了毒性测试。 [参考:19]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号