首页> 外文期刊>Water Science and Technology >Reactive textile dye colour removal in a sequencing batch reactor [Review]
【24h】

Reactive textile dye colour removal in a sequencing batch reactor [Review]

机译:顺序批处理反应器中反应性纺织品染料的脱色[评论]

获取原文
获取原文并翻译 | 示例
           

摘要

dTwo sequencing batch reactors (SBRs) with sequenced anaerobic/aerobic phases were used to study biological colour removal from a simulated cotton textile effluent containing an azo reactive dye. One of the reactors was daily fed with Remazol Brilliant Violet 5R dye and the other was used as control. When operating with a sludge retention time (SRT) of 15 days the total COD removal was around 80%, with 30% being removed anaerobically. After 40-50 days of acclimatization the colour removal efficiency reached a maximum, stable value of 90% from a feed dye concentration of 90 mg/l, almost all being removed during the anaerobic phase. This colour removal was attributed to microbial degradation rather than adsorption and colour removal capacity was not lost even after a seven-day absence of dye in the fed substrate. The dye-fed reactor experienced a reduction in the ORP values attained during the non-aerated phase, after acclimatization, an effect not observed in the dye-free control. Under denitrifying conditions it was observed that the decolouration levels achieved in the anaerobic phase decreased from 90% to 70% after only two cycles with a feed containing 45-60 mg NO3/l. Reduction of the SRT value from 15 to 10 days reduced the biomass concentration from 2.0 to 1.2 g VSS/l and lowered colour removal levels from 90% to 30-50%. When the SRT value was increased back to 15 days the colour removal capacity of the system was completely recovered, suggesting that with a SRT of 10 days the adequate microbial population could not be installed in the reactors. [References: 23]
机译:d使用具有顺序厌氧/好氧相的两个顺序批处理反应器(SBR),研究了从含偶氮活性染料的模拟棉纺织废水中去除生物色的方法。每天向其中一个反应器中加入Remazol Brilliant Violet 5R染料,另一个用作对照。当污泥保留时间(SRT)为15天时,总COD去除率约为80%,而厌氧去除率则为30%。适应40-50天后,从90 mg / l的进料染料浓度中,脱色效率达到最大稳定值90%,几乎全部在厌氧阶段被去除。这种脱色归因于微生物降解而不是吸附,并且即使在进料的基材中不存在染料七天后,脱色能力也不会丧失。染后的反应器在适应环境后,在非充气阶段达到的ORP值降低,这在无染料对照中未观察到。在反硝化条件下,观察到厌氧相中所达到的脱色水平仅在两个循环中以45-60 mg NO3 / l的进料从90%降至70%。将SRT值从15天降低到10天,可将生物量浓度从2.0 VSS / l降低到1.2 g VSS / l,并​​将颜色去除水平从90%降低到30-50%。当SRT值增加到15天时,系统的脱色能力已完全恢复,这表明SRT为10天时,无法在反应器中安装足够的微生物种群。 [参考:23]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号