首页> 外文期刊>Water Science and Technology >Nitrate removal rate in a continuous column denitrification reactor using hydrogen generated by electrolysis with carbon anodes and stainless cathodes
【24h】

Nitrate removal rate in a continuous column denitrification reactor using hydrogen generated by electrolysis with carbon anodes and stainless cathodes

机译:使用碳阳极和不锈钢阴极电解产生的氢气在连续塔式反硝化反应器中的硝酸盐去除率

获取原文
获取原文并翻译 | 示例
           

摘要

An autotrophic continuous denitrification process, using hydrogen generated by electrolysis with activated carbon anodes, was experimentally demonstrated to be an effective nitrate removal process. Several fixed bed columns with polypropylene packing and honeycomb shaped activated carbon anodes and stainless rod cathodes were set in a thermostat chamber at 30degreesC, and potassium nitrate enriched tap water as influent was supplied at various flow rates and electric currents. Although the anode is in the same column where microbial biomass grows, sufficient nitrate removal was observed. For example, almost complete removal of nitrate and nitrite was observed at a hydraulic retention time (HRT) as short as 1.8 h. A model assuming successive denitrification reactions and plug-flow process, nitrate reduction rate = k(1) [NO3-] [H-2], and nitrite reduction rate = k(2) [NO2-]H-2](1.5) was proposed. Calculated results with k(1) = 1.3 mmol(-1) h(-1) and k(2) = 3.3 mmol(-1.5).h(-1) agreed well with all the experimental results. [References: 7]
机译:通过使用活性炭阳极电解产生的氢气,自养连续反硝化过程被证明是一种有效的硝酸盐去除过程。将几个带有聚丙烯填料,蜂窝状活性炭阳极和不锈钢棒阴极的固定床色谱柱放在30°C的恒温槽中,并以各种流速和电流供应富含硝酸钾的自来水作为进水。尽管阳极位于微生物生物量生长的同一列中,但已观察到足够的硝酸盐去除。例如,在短至1.8小时的水力停留时间(HRT)上观察到硝酸盐和亚硝酸盐几乎被完全去除。假定连续进行反硝化反应和活塞流过程的模型,硝酸盐还原率= k(1)[NO3-] [H-2],亚硝酸盐还原率= k(2)[NO2-] H-2](1.5)被提出。 k(1)= 1.3 mmol(-1)h(-1)和k(2)= 3.3 mmol(-1.5).h(-1)的计算结果与所有实验结果吻合得很好。 [参考:7]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号