Over a period of 6 months, pilot plant investigations were carried out with the purpose of bulking sludge control with different aerobic selectors. The wastewater was dominated by industrial dischargers, containing volatile fatty acids up to 450 mg/l. With complete-mix-selectors it was not possible to achieve a stable SVI below 150 ml/g. The bulking sludge could only be controlled with a sectionalized selector (HRT 5-8 minutes per section). The SVI decreased to values below 100 ml/g. Shock-loads and increased VFA-concentrations (by dosing NaC2H3OO) did not cause filamentous growth. [References: 6]
机译:在6个月的时间内,进行了中试工厂调查,目的是使用不同的好氧选择器来控制污泥的体积。废水主要由工业排放器控制,排放的挥发性脂肪酸含量高达450 mg / l。使用完全混合选择器,不可能获得低于150 ml / g的稳定SVI。散装污泥只能用分段选择器控制(每节HRT 5-8分钟)。 SVI降至低于100 ml / g的值。冲击负荷和增加的VFA浓度(通过添加NaC2H3OO)并未引起丝状生长。 [参考:6]